13
14. USER OPTION MODE
a. This allows the user to choose various operation methods.
b. Open the oven door and press “2” for 5 seconds. The buzzer sounds once to indicate User Option Mode is activated.
c. The LED will display “OP: --“.
d. Press any number key to enter related mode setting. Please refer to the chart below for options.
1. Example: to set the buzzer of key beep volume to “Medium,” press “2”. “OP:22” will display on the screen.
2. To change, continue pressing “2”. The LED will cycle “OP:20”, “OP:21”, "OP:22”, “OP:23”, etc.
3. Press
[START]
to save the current setting. After the setting has been saved, “OP: --“ will display again.
4. During the programming process, press
[STOP]
to enter Door Open Mode. Closing the door will have the oven enter Ready Mode.
5. If
[START]
is not pressed as the last step, the program will not be saved.
15. SERVICE MODE
a. Open the oven door and press "3" key for 5 seconds to enter service mode. The screen will display "SERVICE".
b. To check the times of closing or opening of the door, press the "3" key to display the times.
c. Press "1" key for Tubes Hours.
d. Press "2" key for Tubes Cycles.
e. Press "3" key for Door Cycles.
f. Press "4" key and
[START]
to clear service information.
g. Only for some models:
h. Press "5" key to run Top Mag. Oven displays amps
i. Press "6" key to run Bottom Mag. Oven displays amps.
j. Press
[START]
to enter Door Open Mode. Close the door will enter Ready Mode.
16. FACTORY-DEFAULT SETTING
This operation will restore all configures to factory-default setting.
a. Press
[START]
and "0", the buzzer sounds once, and the screen will display "CHECK".
b. If it is in the factory-default setting, the screen will display "11", after three seconds, the oven will turn to the ready mode. Press
[STOP]
to
cancel the display.
c. If not in factory-default setting, the screen will display "00", press
[START]
to reset to factory-default setting. The screen will display
"CLEAR", the buzzer sounds once, and screen will display "11" or "00". If you do not press
[START]
when screen displays "00", setting will
cancel.
Operation