background image

6

60706-238/H

PREPARING THE UNIT 

UNPACKING

CAUTION: EQUIPMENT DAMAGE

THIS UNIT HAS BEEN SHIPPED WITH OIL. Failure to 

maintain the engine oil at the proper level will result in 

serious engine damage.

When you unpack your engine-generator set be sure to 

remove all the information sheets and manuals from the 

carton.

1. As you receive your unit, it is critical to check it for any 

damage. If any damage is noted, it is always easiest to 

refuse the shipment and let  WINCO take care of the freight 

claim. If you sign for the unit, the transfer of the ownership 

requires that you file the freight claim

2. Before proceeding with the preparations of your new 

generator for operation, take a couple of minutes to ensure 

the unit you have received is the correct model and review 

the specification pages in this manual to ensure that this 

unit meets your job requirements.

CAUTION: EQUIPMENT DAMAGE

Failure to remove the shipping restraints will result in 

damage to the unit. 

A shipping restraint has been installed around an engine 

and a generator end shock mount to avoid damage during 

transit. Remove the shipping restraints by loosening the 

top and bottom shock mount bolts. After loosening, the 

restraint will slide out. Tighten the shock mount bolts. 

LUBRICATION

Before starting the engine, check the oil level. This unit was 

shipped with oil. The engine normally holds 34.8 ounces 

(1.2 quarts) of oil. When filling the crankcase, use the 

dipstick to ensure that you do not over fill the crankcase. 

The full oil level mark on the dipstick is depicted in the 

following image.

Oil is added to the engine by removing the oil cap and 

adding oil at this point. After filling the crankcase to the 

proper level, be sure you properly tighten the oil fill cap. 

NOTE: This engine generator must be on a level surface 

before you check or add oil to the system.

The necessity of using the correct oil and keeping the 

crankcase full cannot be overemphasized. Engine failures 

resulting from inadequate or improper lubricant are 

considered abuse and not covered by the generator or 

engine manufacturer’s warranty.

OIL RECOMMENDATIONS

Outdoor temperatures determine the proper oil viscosity for 

the engines. Winco recommends our 5W-30 fully synthetic 

oil to give you excellent protection in cold temperatures 

while maintaining excellent performance in warmer 

weather.

FUEL CONSUMPTION

(Full Load)

Gasoline   1 

gal/hr

Natural Gas  

 

160 ft

3

/hr 

  163,200 

BTU/hr

GASOLINE

When using gasoline, always use fresh, clean, unleaded 

fuel. This engine is certified to operate on unleaded gasoline 

with a minimum octane rating of 87 or higher. Gasoline 

containing no more than 10% ethanol is accepted.

CAUTION: EQUIPMENT DAMAGE

Do not use unapproved gasolines, such as E15 or E85. 

Do NOT mix oil in the gasoline. Use of unapproved 

fuels will damage the engine components and void the 

engine warranty.

Use of fuels with content of ethanol greater than shown 

above, may cause starting and/or performance problems. 

Always ensure that the fuel is clean and free of all debris.

WARNING: FIRE DANGER

Gasoline and its fumes are VERY explosive when 

proper precautions are not taken.

ENGLISH

ENGINE OIL

Recommended Oil

Oil Level Check

Oil Change

AMBIENT TEMPERATURE

OIL FILLER

CAP

UPPER LIMIT
LOWER LIMIT

OIL LEVEL DIPSTICK

UPPER

LIMIT

LOWER

LIMIT

SEALING WASHER

DRAIN BOLT

OIL FILLER CAP

OIL LEVEL DIPSTICK

Synthetic 5W-30

8

Use 4-stroke motor oil that meets or exceeds the requirements for
API service category SJ or later (or equivalent). Always check the
API service label on the oil container to be sure it includes the
letters SJ or later (or equivalent).

Check the engine oil level with the engine stopped and in a level
position.

Start the engine and let it idle for 1 or 2 minutes. Stop the engine
and wait for 2 or 3 minutes.

Remove the oil level dipstick and wipe it clean.

Fully insert the oil level dipstick, then remove it to check the oil
level.

If the oil level is low, remove the oil filler cap, and fill with the
recommended oil to the upper limit mark on the oil level dipstick.

Reinstall the oil level dipstick and oil filler cap.

The Oil Alert system (applicable types) will automatically stop the
engine before the oil level falls below the safe limit. However, to
avoid the inconvenience of an unexpected shutdown, always
check the engine oil level before startup.

Oil is a major factor affecting performance and service life.
Use 4-stroke automotive detergent oil.

Drain the used oil when the engine is warm. Warm oil drains
quickly and completely.

Place a suitable container below the engine to catch the used oil,
then remove the oil filler cap, drain bolt and sealing washer.

Allow the used oil to drain completely, then reinstall the drain
bolt and new sealing washer, and tighten the drain bolt securely.

Please dispose of used motor oil in a manner that is compatible
with the environment. We suggest you take used oil in a sealed
container to your local recycling center or service station for
reclamation. Do not throw it in the trash, pour it on the ground,
or pour it down a drain.

Reinstall the oil filler cap and oil level dipstick securely.

The Oil Alert system (applicable types) will automatically stop
the engine before the oil level falls below the safe limit.
However, to avoid the inconvenience of an unexpected
shutdown, fill to the upper limit, and check the oil level regularly.

With the engine in a level position, fill with the recommended oil
to the upper limit mark on the oil level dipstick.

Running the engine with a low oil level can cause engine damage.

This type of damage is not covered by the Distributor’s Limited
Warranty.

Running the engine with a low oil level can cause engine

damage. This type of damage is not covered by the Distributor’s
Limited Warranty.

SAE 10W-30 or 5W-30 is recommended for general use. Use a full
synthetic 5W-30 for starting/operating temperatures between 5°F
( 15°C) and

13°F ( 25°C). Other viscosities shown in the chart

may be used when the average temperature in your area is within
the indicated range.

1.

2.

3.

4.

5.

1.

2.

3.

4.

09/07/07 20:34:57 32Z6L600_008

Summary of Contents for HPS6000HE/I

Page 1: ...ber as yours If you should ever need to contact us concerning this unit it will help us to respond to your needs faster MODEL _________________________________________________ SERIAL NUMBER _________________________________________ PURCHASE DATE _________________________________________ DEALER NAME ___________________________________________ DEALER PHONE ________________________________________ ...

Page 2: ...SPARK PLUG CARBON CANISTER GENERATOR CARE 18 EXERCISING THE GENERATOR GENERATOR MAINTENANCE CLEANING TROUBLESHOOTING 18 RECEPTACLE WIRING DIAGRAM 19 CA EVAP EMISSION CONTROL 20 LIMITED WARRANTY 20 SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the generator Read and understand all instructions in the manual before ...

Page 3: ...turer Mecc Alte Spa Generator Model Number S16W 130 A Part Number 16346 006 Rotor Resistance 3 95 Ohms Stator Resistance 0 36 Ohms Cap Winding Resistance 2 45 Ohms Capacitors 25 mF Capacitor Part Number 16346 612 ENGINE Engine Manufacturer Honda Engine Model Number GX340 Type RT2VWE2 Code GCBET Spark Plug Gap 0 030 in Intake Valve Clearance 0 006 0 010 in Exhaust Valve Clearance 0 010 0 012 in Oil...

Page 4: ...the earth 2 FIRE HAZARD Gasoline and other fuels present a hazard of possible explosion and or fire A Do not refuel when the engine is running or hot B Keep fuel containers out of reach of children C Do not smoke or use open flame near the generator set or fuel tank D Keep a fire extinguisher nearby and know its proper use Fire extinguishers rated ABC by NFPA are appropriate E Store fuel only in a...

Page 5: ...ds The diagram below represents this 5 500 watt rated output generator A B represent the 120 volt output legs of this generator Up to 2 250 watts at 120 volts 22 9 Amps can be drawn from the receptacles attached to either A or B output legs This generator is capable of producing 22 9 Amps of 240 volt current at C Check the appliance or tool nameplates for the current and voltage to insure compatib...

Page 6: ...el This engine is certified to operate on unleaded gasoline with a minimum octane rating of 87 or higher Gasoline containing no more than 10 ethanol is accepted CAUTION EQUIPMENT DAMAGE Do not use unapproved gasolines such as E15 or E85 Do NOT mix oil in the gasoline Use of unapproved fuels will damage the engine components and void the engine warranty Use of fuels with content of ethanol greater ...

Page 7: ... with your local fuel supplier to ensure complete compliance with ALL codes 1 Remove the plastic cover plug from the demand regulator 2 Connect the flex fuel line to the demand regulator or the optional solenoid A positive fuel shut off device must be installed in the fuel line close to the engine generator set This manual shut off valve is required by code even if the 12 Volt fuel solenoid kit is...

Page 8: ...onnect the ridged mounted pipe directly 6 Turn on the vapor fuel 7 Start the engine 8 Apply the load to the generator NG TO GASOLINE 1 With the engine running turn off the NG fuel supply 2 Run the engine until it runs out of fuel 3 Remove the flexible fuel line from the demand regulator 4 Reinstall the plastic insert in the regulator 5 Check to be sure the gasoline fuel valve is off 6 Fill the gas...

Page 9: ...nect the positive battery cable to the bat terminal first Then connect the negative battery cable to the bat terminal Make sure all connections are clean and tight Reverse the sequence when disconnecting disconnect the negative cable first The engines produce enough direct current to keep the battery charged under normal operating conditions but were not intended to be used as a battery charger WA...

Page 10: ...low a certain point the low oil module on the engine will shut it down This oil warning system will automatically stop the engine before the oil level reaches a critical danger point This feature is designed to prevent costly repairs and downtime CAUTION EQUIPMENT DAMAGE Allowing the engine to shutdown repeatedly on low oil level may cause excessive wear which can be cumulative ...

Page 11: ...rip lightly until resistance is felt then pull briskly 6 When the engine starts open the choke gradually 7 The engine should promptly come up to operating speed NOTICE Do not allow the starter grip to snap against the en gine Return it gently to prevent damage to the starter CAUTION EQUIPMENT DAMAGE Never permit the choke to remain on after the engine has run for a short time It is not necessary t...

Page 12: ... Because the engine vacuum needs to activate the fuel system it is almost impossible to manual start the unit using NG 1 Check oil level refill as needed 2 Turn on the NG fuel supply 3 NEVER use the choke when operating on NG 4 Turn the engine switch to the on position 5 Operating the starter Rotate the key switch briefly to START position The starter life is improved by using shorter starting cyc...

Page 13: ...do so could result in damage to equipment plugged into the unit and possi ble injury to the individual All engines have a tendency to slow down when a load is applied When the electrical load is connected to the generator the engine is more heavily loaded and as a result the speed drops slightly This slight decrease in speed together with the voltage drop within the generator itself results in a s...

Page 14: ...erator at these sites a secondary emergency distribution panel may have to be installed The emergency distribution panel must be installed by a licensed electrician according to all CONNECTING THE LOADS APPLYING THE LOADS Allow the engine to warm up for two or three minutes before applying any load This will allow the engine to reach normal operating temperature and oil to circulate throughout the...

Page 15: ...load on the generator during the initial start up See the nameplate on your generator for the amperage capabilities of your unit CAUTION EQUIPMENT DAMAGE Failure to properly limit and balance the load applied to the generator will cause the generator to produce low voltage and may damage the engine generator set It may also cause severe damage to the loads con nected to the generator at that time ...

Page 16: ...ecommendation section in this manual NOTE This engine requires 38 4 ounces 1 2 qt of oil if completely drained Use caution when refilling the engine as some residual oil may have remained in the engine Always use the dipstick when filling the engine with oil to prevent overfilling E Replace filler plug F Start engine up and warm it up G After warming up the engine recheck the oil level and refill ...

Page 17: ... every 300 hours of operation Always replace with the same spark plug that came in the engine and check gap before installing Spark plug gap is 0 030 Poor spark will also occur if spark plug wire does not fit firmly on spark plug If this happens reform the terminal to fit firmly on spark plug tip CARBON CANISTER Designed to collect store and dispose of fuel vapors created in the fuel tank fuel sys...

Page 18: ...roperly should it be needed in an emergency GENERATOR MAINTENANCE Any major generator service including the installation or replacement of parts should be performed only by a qualified electrical service technician USE ONLY FACTORY APPROVED REPAIR PARTS A Bearing The bearing used in these generators is a heavy duty double sealed ball bearing They require no maintenance or lubrication B Receptacles...

Page 19: ...19 60706 238 H GND GND G ND GND GND GND G3 G3 N N N N N N N G3 G1 G1 G1 G1 G1 G1 G1 G1 G1 G3 RECEPTACLE WIRING DIAGRAM ...

Page 20: ...sole remedy for a failure under this warranty shall be limited to the repair of the product At WINCO s option material found to be defective in material or workmanship under normal use and service will be repaired or replaced For warranty service return the product within the warranty period to your nearest WINCO Authorized Service Center or to WINCO in Le Center Minnesota Duration Consumer Commer...

Reviews: