2.
Checking the Oil Level
: The oil level must al-
ways be checked before the engine is started. Take
care to remove any dirt or debris from around the
oil fill plug before removing. Be sure the oil level is
maintained. Fill to the “
FULL
” mark on the dipstick.
3.
Dual Element Air Filter
: Clean and or replace
foam pre-cleaner and air filter annually or every 100
hours. Service more often under dusty conditions.
WARNING: EQUIPMENT DAMAGE
Never start or run the engine with the air filter re-
moved
a. Loosen snaps (Ref “A”) and remove cover.
Ref “B”
b. Remove the nut (Ref “D”) and the retainer.
(Ref “E”)
c. Remove the air filter. (Ref “F”)
d. Remove the pre-cleaner (Ref “G”) from the air
filter.
e. To loosen debris, gently tap the air filter on a
hard surface. If the air filter is excessively dirty,
replace with a new filter.
Notice
: Do not use pressurized air or solvents to
clean the filter. Pressurized air can damage the filter
and solvents will dissolve the filter.
f. Wash the pre-cleaner in liquid detergent and
water. Then allow it to thoroughly air dry.
DO NOT
oil the pre-cleaner.
g. Install foam pre-cleaner to the air filter.
h. Install the air filter and secure with retainer and
nut
I Install and secure the cover.
4.
Spark Plug
: Replace annually or every 100 hours
of operation. Always replace with the same spark
plug that came in the engine and check gap before
installing. Spark plug gap is 0.030”. Poor spark will
also occur if spark plug wire does not fit firmly on
spark plug. If this happens, reform the terminal to fit
firmly on spark plug tip.
5.
Carbon Canister:
Designed to collect, store, and
dispose of fuel vapors created in the fuel tank / fuel
system. The canister should last the life of the unit as
long as it stays dry.
GENERATOR CARE
Proper care and maintenance of the generator is
necessary to ensure a long trouble free life.
1.
Exercising The Generator
- The generator
should be operated every three to four weeks. It
should be operated for a period of time sufficient to
warm the unit up and to dry out any moisture that has
accumulated in the windings. If left, this moisture can
cause corrosion in the winding. Frequent operation
of the engine generator set will also insure that the
set is operating properly should it be needed in an
emergency.
2.
Generator Maintenance
- Any major genera-
tor service, including the installation or replacement
of parts, should be performed only by a qualified
electrical service technician.
USE ONLY FACTORY
APPROVED REPAIR PARTS
.
a. Bearing - The bearing used in these generators
is a heavy duty double sealed ball bearing.
They require no maintenance or lubrication.
b. Receptacles - Quality receptacles have been
utilized. If a receptacle should become cracked
or otherwise damaged, replace it. Using dam-
aged or cracked receptacles can be both dan-
gerous to the operator and destructive to the
equipment.