CALIFORNIA EVAPORATIVE EMISSION CONTROL

WARRANTY STATEMENT

YOUR WARRANTY RIGHTS AND OBLIGATIONS

The California Air Resources Board is pleased to explain the evaporative emission control system’s war-
ranty on your model 2013 or later generator.  In California, new equipment that uses small off-road engines 
must be designed, built, and equipped to meet the State’s stringent anti-smog standards.  WINCO must 
warrant the evaporative emission control system on your generator for the period listed below provided 
there has been no abuse, neglect or improper maintenance of your equipment.  

Your evaporative emission control system may include parts such as: carburetor, fuel tanks, fuel lines, fuel 
caps, valves, canisters, fi lters, vapor hoses, clamps, connectors and other associated components.

MANUFACTURER’S WARRANTY COVERAGE

The evaporative emission control system is warranted for two years.  If any evaporative emission related 
parts on your equipment are defective, the parts will be repaired or replaced by WINCO.

OWNER’S WARRANTY RESPONSIBILITIES:

As the generator owner, you are responsible for performance of the required maintenance listed in your 
owner’s manuals. WINCO recommends that you retain all receipts covering maintenance on your genera-
tor, but WINCO cannot deny warranty solely for lack of receipts.

As the generator owner, you should be aware that WINCO may deny you warranty coverage if your genera-
tor or a part has failed due to abuse, neglect, or improper maintenance or unapproved modifi cations. 

You are responsible for presenting your generator to a WINCO service center as soon as the problem ex-
ists. The warranty repairs should be completed in a reasonable amount of time, not to exceed 30 days.  If 
you have a question regarding your warranty coverage, you should contact WINCO at 507-357-6831.

Summary of Contents for 15041-006

Page 1: ...INSTALLATION AND OPERATORS MANUAL PORTABLE GENERATORS DL5000H D DL6000H F WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 wincogen com...

Page 2: ...ing 8 Electric Starting 8 Stopping Storage 9 Operating Speed 9 CONNECTING THE LOADS 10 Wiring 10 ENGINE CARE 11 GENERATOR CARE 12 TROUBLESHOOTING 13 CONTROL PANEL WIRING DIAGRAM 14 WARRANTY INFORMATIO...

Page 3: ...dren c Do not smoke or use open flame near the generator set or fuel tank d Keep a fire extinguisher nearby and know its proper use Fire extinguishers rated ABC by NFPA are appropriate e Store fuel on...

Page 4: ...3rd party companies making enclosures for generators that have been properly engineered The use of these 3rd party enclosures is acceptable as long as they have been certified and meet current code DO...

Page 5: ...s in good order when shipped Inspect the generator set promptly after receiving it If any damage is noted notify the trans portation company immediately request proper pro cedures for filing a conceal...

Page 6: ...perate it Units equipped with a recoil or rope start will operate satisfactorily without a battery WARNING EQUIPMENT DAMAGE The battery positive cable is shipped with a plastic protective cap When sta...

Page 7: ...ed inside the engine If the oil level drops below a certain point the low oil module on the engine will shut it down This low oil warning system will automatically stop the engine before the oil level...

Page 8: ...ith time to cool off between cranking cycles Do not operate the starter more than 5 seconds and wait at least 10 seconds before operating the starter again Repeat cycle if necessary 6 When the engine...

Page 9: ...chart Although individual units and models vary slightly the normal voltage and frequency of the engine gen erator described in this manual are approximately as follows under varying loads LOAD VS OUT...

Page 10: ...ll state and local codes and regulations Check with local authorities before proceeding WARNING PERSONAL DANGER A fully isolated double pole double throw manual transfer switch must be installed any t...

Page 11: ...The oil level must al ways be checked before the engine is started Take care to remove any dirt or debris from around the oil fill plug before removing Be sure the oil level is maintained Fill to the...

Page 12: ...tion or replacement of parts should be performed only by a qualified electrical service technician USE ONLY FACTORY APPROVED REPAIR PARTS a Bearing The bearing used in these generators is a heavy duty...

Page 13: ...Shorted capacitor Shorted diodes on rotor GFCI Receptacle tripped SPECIFICATIONS DL5000H D Generator manufacturer WINCO Inc Part number 15359 039 Rotor resistance 0 83 Ohms Stator resistance G1 N 0 6...

Page 14: ...3310 00 14 60707 126 WIRING DIAGRAMS...

Page 15: ...e repaired or replaced For warranty service return the product within 24 months from the date of purchase transportation charges prepaid to your nearest WINCO Authorized Service Center or to WINCO Inc...

Page 16: ...RER S WARRANTY COVERAGE The evaporative emission control system is warranted for two years If any evaporative emission related parts on your equipment are defective the parts will be repaired or repla...