background image

 

WINAICO is a trademark of Win Win Precision Technology Co., Ltd.

 

www.winaico.com

 

SIM2205-01(EN) 

 

 

 

          1 

1.

 

Introduction 

 

Thank you for choosing WINAICO for your solar system.  
 
This  manual  is  intended  for  qualified  solar  designers  and  installers  to  assist  in  the  correct  installation,  operation  and 
maintenance of WINAICO’s WSP and WST series solar panels. WINAICO solar panels should only be installed by qualified 
professionals authorised to carry out such work by their relevant local jurisdiction. Unqualified people should be kept a 
safe distance away.   
 
All relevant standards and local regulations must be followed. Failure to adhere to the instructions in the manual and to 
local  requirements  may  void  product  warranties.  Improper  installation  of  solar  panels  can  be  a  safety  hazard  and will 
result in low systems yields.  
 
WINAICO solar  modules are  covered by product warranties accessible from our  website and through our local offices. 
We recommend that you insure your WINAICO photovoltaic system from natural and other hazards (e.g. lightning strikes, 
vandalism).  
 
If there are any points of ambiguity WINAICO recommends confirming proposed designs in writing before the time of 
installation. Contact details are at the end of this document if you require further information or clarification. Feedback 
on how we may improve this document is welcome.  

 

Exclusion clause

 

 

These instructions only apply to WINAICO products. WINAICO does not accept liability for any damage resulting from 
failure  to  observe  the  requirements  listed.  Please  note  that  the  person  mounting  the  system  is  responsible  for 
connecting and sizing the system as well as compliance with all the safety specifications applicable to configuration and 
installation. WINAICO assumes no responsibility beyond the proper function and safety of the modules. Also note the 
installation instructions for other system components which may form part of the overall system. A structural analysis 
may have to be produced for the entire project. 

 

Please consult our website 

https://www.winaico.com/

 for more details. 

 

 

 

Summary of Contents for WST-MG 6X18

Page 1: ...WINAICO is a trademark of Win Win Precision Technology Co Ltd www winaico com SIM2205 01 EN Installation Manual Crystalline modules...

Page 2: ...l installation 12 Module selection 12 Diodes and fuses 12 Cables and connectors 13 Safetyprecautions 14 6 3 Grounding 14 7 CLEANING AND MAINTENANCE 15 8 LIABILITY DISCLAIMER 16 9 CONTACTS 16 Win Win P...

Page 3: ...s We recommend that you insure your WINAICO photovoltaic system from natural and other hazards e g lightning strikes vandalism If there are any points of ambiguity WINAICO recommends confirming propos...

Page 4: ...a 1 600 Pa 3 600 Pa 1 600 Pa Max test load push pull 5 400 Pa 2 400 Pa 5 400 Pa 2 400 Pa 5 400 Pa 2 400 Pa Module series WST MGL 6X20 WST MG 6X20 WST MG 6X18 Dimensions mm 1 767 x 1 050 x 35 1 759 x 1...

Page 5: ...WINAICO is a trademark of Win Win Precision Technology Co Ltd www winaico com SIM2205 01 EN 3 WST MGX P3 6X18 WST MGX P1 6X18 WST MGX E1 6X18...

Page 6: ...WINAICO is a trademark of Win Win Precision Technology Co Ltd www winaico com SIM2205 01 EN 4 WST MGL 6X20 WST MG 6X20 WST MG 6X18...

Page 7: ...s are between 40 C and 85 C Hazardous voltages IEC 61730 higher than 50V DC EN61730 higher than 120V DC hazardous power applications higher than 240W where general unrestricted access is anticipated M...

Page 8: ...s Many issues caused by rough handling will arise years after the installation Taking additional care can save considerable time and money from avoided service calls and replacements It is recommended...

Page 9: ...terials Solar modules are non explosion protectedequipment Mounting site Orientation The performance of WINAICO Panels is dependent on the available solar resource as well as their positioning in rela...

Page 10: ...tion work in high winds Secure yourself and other persons against falling Prevent the possibility of falling objects Secure the work area so that no other persons can be injured Keep children away fro...

Page 11: ...Figure below for each fastening point must have an area of at least 135 mm 2 A torque wrench must be used for assembly In the examples shown the tightening torque using M8 bolts produced from V2A is 2...

Page 12: ...600 Pa Rear pull 1600 Pa WST MGX E1 6X18 Test Load Front push 5400 Pa Test Load Front push 2400 Pa Rear pull 2400 Pa Rear pull 2400 Pa Design Load Test load 1 5 Front push 3600 Pa Design Load Test loa...

Page 13: ...00 Pa Rear pull 1600 Pa WST MG 6X18 Test Load Front push 5400 Pa Test Load Front push 2400 Pa Rear pull 2400 Pa Rear pull 2400 Pa Design Load Test load 1 5 Front push 3600 Pa Design Load Test load 1 5...

Page 14: ...odule meets the technical requirements of the system as a whole Ensure that other system components do not exert damaging mechanical or electrical stresses on the module When connected in series modul...

Page 15: ...long periods Select the appropriate cable size according to its length to avoid voltage drop Connectors of different brands and models cannot be mated ATTENTION WINAICO connectors protection level is...

Page 16: ...ialist ATTENTION High voltage direct current can occur even at low levels of radiation Never touch exposed live cables 6 3 Grounding Proper grounding on the module frames is the responsibility of the...

Page 17: ...used only for maintaining mechanical connections and holding electrical grounding devices in the proper position for electrical conductivity Such devices where supplied with the module and evaluated...

Page 18: ...o liability shall be borne for infringements of patent laws or other rights of third parties which result from the use of the modules unless mandated by law 9 Contacts If you have any questions our WI...

Reviews: