background image

 

WINAICO is a trademark of Win Win Precision Technology Co., Ltd.

 

www.winaico.com

 

SIM2205-01(EN) 

 

 

 

          13 

event of a malfunction (e.g. an inverter defect). The fuses must be configured according to the  maximum series fuse 
rating, which is quoted in the datasheets pertaining to the respective modules. 

 

Cables and connectors

 

 

A PV module has a pair of male and female waterproof connectors. 

 

 

Connect the output cable to the other equipment in the system correctly. 

 

Connect the required number of PV modules to meet the voltage specification of other equipment used in the 
PV system. 

 

Wire the output cable connectors so they do not exert any force or pressure on the PV module’s junction box. 
Attach the cable to the mounting frame using approved fasteners. The connectors should be placed behind the 
mounting frame so that the connectors can’t be directly exposed to sunlight, wind and rain. 

 

To  extend  the  cable,  use  certified  solar  cables  and  connectors  that  can  withstand  outdoor  use  for  long 
periods. Select the appropriate cable size according to its length to avoid voltage drop. 

 

Connectors of different brands and models cannot be mated. 

 

ATTENTION

:  WINAICO  connectors’  protection  level  is  IP68.  They  cannot  be  under  water  for  a  long  time. 

Sunlight  exposure and immersion  in water of the connectors should be avoided. Do not allow installed 
PV connectors and  cables to be in contact with the roof surface or the ground. 

 

ATTENTION

:  Faulty  connections  can  result  in  arcs  and  electrical  shock.  Check  that  all  electrical 

connections  are  securely fastened. Make sure that all locking connectors are fully engaged and locked. 

 

 

 

 

 

ATTENTION: 

 

To  prevent  electric  shocks,  please  turn  off  the  power  when  installing  PV  connectors.  Do  not  pull  apart 
the PV connector under load. Turn off the DC/AC inverter or turn on DC circuit breaker to disconnect PV 
connectors  from load. Then insert and extract under voltage is permitted.

 

 

 

ATTENTION:  

The cable must not be bent or crushed at the joints to connectors and junction box. A minimum bending 
radius  R≥5×cable  diameter  must  be  maintained.  The  cable  must  be  routed  in  a  way  that  tensile 

stress  on  the  conductor or connection is prevented.

 

 

 

 

 

 

 

 

 

Summary of Contents for WST-MG 6X18

Page 1: ...WINAICO is a trademark of Win Win Precision Technology Co Ltd www winaico com SIM2205 01 EN Installation Manual Crystalline modules...

Page 2: ...l installation 12 Module selection 12 Diodes and fuses 12 Cables and connectors 13 Safetyprecautions 14 6 3 Grounding 14 7 CLEANING AND MAINTENANCE 15 8 LIABILITY DISCLAIMER 16 9 CONTACTS 16 Win Win P...

Page 3: ...s We recommend that you insure your WINAICO photovoltaic system from natural and other hazards e g lightning strikes vandalism If there are any points of ambiguity WINAICO recommends confirming propos...

Page 4: ...a 1 600 Pa 3 600 Pa 1 600 Pa Max test load push pull 5 400 Pa 2 400 Pa 5 400 Pa 2 400 Pa 5 400 Pa 2 400 Pa Module series WST MGL 6X20 WST MG 6X20 WST MG 6X18 Dimensions mm 1 767 x 1 050 x 35 1 759 x 1...

Page 5: ...WINAICO is a trademark of Win Win Precision Technology Co Ltd www winaico com SIM2205 01 EN 3 WST MGX P3 6X18 WST MGX P1 6X18 WST MGX E1 6X18...

Page 6: ...WINAICO is a trademark of Win Win Precision Technology Co Ltd www winaico com SIM2205 01 EN 4 WST MGL 6X20 WST MG 6X20 WST MG 6X18...

Page 7: ...s are between 40 C and 85 C Hazardous voltages IEC 61730 higher than 50V DC EN61730 higher than 120V DC hazardous power applications higher than 240W where general unrestricted access is anticipated M...

Page 8: ...s Many issues caused by rough handling will arise years after the installation Taking additional care can save considerable time and money from avoided service calls and replacements It is recommended...

Page 9: ...terials Solar modules are non explosion protectedequipment Mounting site Orientation The performance of WINAICO Panels is dependent on the available solar resource as well as their positioning in rela...

Page 10: ...tion work in high winds Secure yourself and other persons against falling Prevent the possibility of falling objects Secure the work area so that no other persons can be injured Keep children away fro...

Page 11: ...Figure below for each fastening point must have an area of at least 135 mm 2 A torque wrench must be used for assembly In the examples shown the tightening torque using M8 bolts produced from V2A is 2...

Page 12: ...600 Pa Rear pull 1600 Pa WST MGX E1 6X18 Test Load Front push 5400 Pa Test Load Front push 2400 Pa Rear pull 2400 Pa Rear pull 2400 Pa Design Load Test load 1 5 Front push 3600 Pa Design Load Test loa...

Page 13: ...00 Pa Rear pull 1600 Pa WST MG 6X18 Test Load Front push 5400 Pa Test Load Front push 2400 Pa Rear pull 2400 Pa Rear pull 2400 Pa Design Load Test load 1 5 Front push 3600 Pa Design Load Test load 1 5...

Page 14: ...odule meets the technical requirements of the system as a whole Ensure that other system components do not exert damaging mechanical or electrical stresses on the module When connected in series modul...

Page 15: ...long periods Select the appropriate cable size according to its length to avoid voltage drop Connectors of different brands and models cannot be mated ATTENTION WINAICO connectors protection level is...

Page 16: ...ialist ATTENTION High voltage direct current can occur even at low levels of radiation Never touch exposed live cables 6 3 Grounding Proper grounding on the module frames is the responsibility of the...

Page 17: ...used only for maintaining mechanical connections and holding electrical grounding devices in the proper position for electrical conductivity Such devices where supplied with the module and evaluated...

Page 18: ...o liability shall be borne for infringements of patent laws or other rights of third parties which result from the use of the modules unless mandated by law 9 Contacts If you have any questions our WI...

Reviews: