20
Description of functions
GB
Symbol (only at mains ope-
rated variant) appears after
use for better recognisability
of the manual release for
the use
(max. active range at close
range reflex: 3 cm)
Function
Abides a user more than 10 secs., an automatic flushing will be released (DIP-Switch 1)
when the user leaves the active range.
(The flushing can be released by magnetic lifter, motor lifter, magnetic valve,...
Adjustment see DIP-Switch 4)
If a user is recognised for more than 1,5 secs. in the active range, a “manual” flushing
can be activated by approaching the hand to the infrared sensor. (see above)
If the user leaves the active range within 10 secs. (dwell time is not reached), it´s
possible to release a “manual” flushing via close range reflex within 60 secs.
Furthermore an additional “manual” flushing can be activated within 60 secs. after an
automatic flushing.
External ventilator
can be operated by the WC-control - connecting terminal see page 21
The follow up time of the ventilator lasts
10 min. (Switch 6)
The ventilator can be activated after 1 min., so the user must be recognised for min.
1 min. in the active range.
CWS CleanSeat (automatic cleaning WC-seat)
Connection is possible via connecting terminal (see page 21).
When the flushing will be released, the CWS CleanSeat will be activated.