38 Shower control
WimTec PROOF S6 -
Hy
Plus
EN
PROOF S6 -
Hy
Plus
Description of the functions
Auto stop:
DIP switch 2
i
Note:
If you accidentally leave the detection range during a shower
while the auto stop function is activated, it is recommended
that you activate the extended shut-off delay of 5 s
(DIP 6 = ON).
This function automatically stops the water flow as soon as the user
leaves the detection range of the fitting.
“ON” position
= auto stop activated.
“OFF” position
= auto stop deactivated (preset).
ON
OFF
2
1
3 4 5 6
Auto stop:
The water flow is automatically stopped once the user
leaves the detection range and the shut-off delay time has
elapsed (see p. 41).
30 - 70 cm