Shower control
WimTec OCEAN P6 with thermal disinfection
25
EN
PROOF P6 with thermal disinfection
Configuring the programs & functions
Program activation – DIP switches 1 and 2:
Program
DIP switch 1
DIP switch 2
Description
Semi automatic mode
1)
OFF
ON
Page 29
Fully automatic mode
ON
ON
Page 30
Manual mode
OFF
OFF
Page 31
Function activation – DIP switches 3–6:
DIP switch
Function
Description
3
Shut-off delay ON = 5 s /
OFF
1)
= 2 s
4
Warm water rinse
1)
Page 32
5
Protection from scalding
1)
Page 33
6
Stagnation rinse
Page 34
C. Range control
User detection range preset
to 50 cm (configurable from
10–50 cm).
Sets the infrared sensor range
from 10–50 cm.
D. Time control
set to safety flow arrest after
10 min (configurable from
10 s to 10 min).
Manual program mode: confi-
gurable from 10–60 s.
After the configured maximum
flow time has elapsed, the
water stops automatically to
prevent unintentional conti-
nuous activation.
E. Interval control
for stagnation rinse, default
setting 48 h (configurable
from 3–48 h).
If the fitting has not been
used for the set period, the
device will automatically
perform a 10-s rinse to clear
stagnation water from the
pipes.
DIP switches:
Regulator controls:
1)
Program or functions already configured ex factory.