34 Shower control
WimTec PROOF P6
EN
PROOF P6
Cleaning stop:
DIP switch 5
Description of the functions
Serves to disable the fitting prior to cleaning.
DIP switch 5 ON = Cleaning stop function enabled (default setting).
DIP switch 5 OFF = Cleaning stop function disabled.
1 2 3 4 5 6
ON
OFF
Halbautomatik:
Vollautomatik:
Manuell:
Warmlauf:
ON
OFF
1 2 3
4
5 6
ON
OFF
1 2
3 4 5 6
ON
OFF
1 2
3 4 5 6
ON
OFF
1 2
3 4 5 6
Reinigungsstopp:
ON
OFF
1 2 3 4
5
6
Hygienespülung:
ON
OFF
1 2 3 4 5
6
60 cm
60 cm
60 cm
60 cm
60 cm
60 cm
60 cm
60 cm
60 cm
60 cm
60 cm
60 cm
50 cm
In fully automatic mode,
you must approach the
infrared sensor with your
hand within one second
after entering the sensor
range to prevent the fitting
from activating.
!
User detection
When you step in front of the
shower, the system will detect
you.
Enable cleaning stop
Approach the infrared sensor
with your hand (see image)
and remove it after the LED
has flashed 5 times.
The cleaning stop remains ena-
bled for 10 min after leaving
the sensor range.
Disable cleaning stop
The function automatically
stops if no user was detected
for 10 minutes.
You can manually disable the
function following the same
procedure used to enable it.
The fitting will resume normal
operation with a safety delay
of 3 s after you leave the