16 Washbasin fitting
WimTec ONE WT
EN
ONE WT
Assembly
1.
Make a pre-flush.
2.
Close shut-off valve. Insert dirt filter.
Then disconnect water supply and power supply. Only reac-
tivate until ceramic is mounted.
3.
Insert magnetic valve with seal. Attention!
Follow flow direc-
tion of magnetic valve. Open shut-off valve.
4.
Connection cable 2-pin (2 x 0.5 mm) to collect sensor.
5.
Infrared sensor must be connected. Any polarity.
6.
Attach micro sensor.
ATTENTION!
Perform the following steps
in the order indicated!
!
1
2
3
4
5