Bath fitting
WimTec OCEAN B7
23
EN
OCEAN B7
Function configuration
Note on bathtub filling control:
The time configured at the bathtub
filling control defines the max.
filling time that can be stored on
any of the three AquaCap buttons
for filling the bathtub.
Regulator controls:
J. DIP switches:
1)
Factory setting
Function activation:
Dip-Switch
Function
DIP setting
1)
Description
1
-
OFF
-
2
Cleaning Stop
OFF
Page 30
3
Memory function
ON
Page 31
4
Intelligent stagnation flush
OFF
Page 32
5
Flushing duration (ON = 20 s /
OFF = 10 s
)
OFF
-
6
-
OFF
-
G.
Interval control
for automatic flushing,
24 h preadjusted
(3 h - 48 h adjustable).
H.
Tub filling control
for flush stop of tub outlet
20 min preadjusted
(5 min - 20 min adjustable)
I.
Hand shower control
for flush stop of hand shower,
20 min preadjusted
(5 min - 20 min adjustable)
3
12
h
48
24
6
5
10
min
20
15
7
5
10
min
20
15
7