Urinal flush control
WimTec MULTI 2
21
EN
MULTI 2
Assembly - 230-V mains version
5
4
1
2
1.
a)
Close integrated stop valve.
b)
Open dirt filter cover.
c)
Remove dirt filter, re-insert dirt filter cover.
2.
a)
Open the integrated stop valve and flush the line,
then close the stop valve again.
b)
Open dirt filter cover.
c)
Re-insert dirt filter and dirt filter cover.
3.
Insert magnetic valve with gaskets.
Observe direction of flow!
4.
Feed cable (3 x 0.75 mm
2
- 1.5 mm
2
) for the power supply
(230 V) into the flush-mount set.
5.
Align the mounting frame and securely fasten.
a
a
b
b
c
c
ATTENTION!
Perform the following steps
in the order indicated!
!
3