ure is cooling down. Additionally, the air pressure is on the maximum value as shown on the
display. As soon as the temperature has cooled down to about 90
, the device stops and
℃
the display will show “off”. Now it is safe to turn the main power supply off.
10. Switch the main power supply off.
11. Disconnect the device from the electricity source.
D. Soldering iron
Connect the soldering iron connection with the six-pin socket at the front of the control panel
(
8
on the control panel).
Follow the instructions for the first use (see paragraph A).
Activate the activation switch “soldering iron” (
11
on the control panel). The temperature of the
soldering iron is automatically increased to 350
(standard).
℃
Adjusting the soldering temperature with the soldering iron adjustment buttons (
6
on the con-
trol panel).
Use the soldering iron as soon as the desired heat has been reached.
Deactivate the soldering iron activation switch.
Let the soldering iron cool down for quite a while, before storing it.
E. Pre-heater
Follow the instructions of the first-time use (paragraph A).
Place the PCB onto the pre-heater to warm up or to rework it.
Activate the pre-heater activation switch (
10
on the control panel). This will increase the tem-
perature of the soldering iron to 100
(standard).
℃
Set the pre-heating temperature by pressing the “pre-heat settings” (
5
on the control panel).
The upper heater can be activated for the reworking of a multiple layered conductor board,
after the PCB has been pre-heated to the desired temperature.
The actual temperature of the conductor board can be measured with the help of the external
sensor, by placing it on the conductor board.
After the reworking has been finished, deactivate the activation switch of the pre-heater.
F. External sensor
Follow the instructions of the first-time use (paragraph A).
Place the PCB onto the pre-heater to warm up or to rework it.
Connect the external sensor probe with the connection of the external sensor (
8
on the control
panel).
When the soldering iron function switch is deactivated push the downward button of the tem-
perature regulator of the soldering iron to activate the functions of the external sensor.
The actual temperature of the conductor board can be measured with the help of the external
sensor, by placing it on the conductor board.
To switch the functions of the external sensor probe off, push the soldering iron up.
Automatic standby mode
Automatic standby mode (heat gun)
This device has a built-in standby mode, e. g. if the heat gun has not been used for a longer period of
time, for example 30 min (standard) with no user input via the temperature adjustment in that time, it
goes into the automatic standby mode.
The system blows air (room temperature) with a maximum speed to decrease the temperature. When
the temperature has decreased to approx. 90
, the heat gun will stop automatically. The display will
℃
show “---,” meaning that the system is in standby mode.
© by WilTec Wildanger Technik GmbH
Item 90866
Page 9
http://www.WilTec.de
http://www.aoyue.eu
01 2021
-1