BEWARE

 

The  use  of  this  device  is  allowed  only  with  fault  current  protection  switch  with  a  triggering  nominal 
current up to 30mA (according to VDE 0100 Article 702 and 738). 
 
The  device  is  not  intended  for  use  by  persons  (including  children)  with  impaired  or  limited  physical, 
sensory and mental abilities or lack of experience and/or real knowledge, unless they are supervised 
by a person responsible for their safety or the follow the instructions, made by this person on how to 
use the device correctly. 

 

Children should be supervised to make sure that they do not play with the device. 

 

ATTENTION

 

 

The head of the compressor (with cooling fins) can get very hot. 

 

Run a visual inspection of the device before every use. Do not use the device if the safety ap-
pliances are damaged or worn out. Never override safety regulations. 

 

Use  the  device  exclusively  according  to  the  intended  purpose  stated  in  the  instructions  for 
use. 

 

You are responsible for the safety of the working environment. 

 

If the cable or the plug is damaged due to external influences the cable must not be repaired! 
It has to be replaced with a new one. This work can be carried out only by an electrician. 

 

The voltage indicated on the type plate of the device of 230 Volt alternating voltage has to cor-
respond to the existent mains voltage. 

 

Never lift, carry or fixate the device by using the power cable.   

 

Make sure that the electrical plug connection is placed in a flood-proof area and is protected 
from moisture. 

 

Disconnect the mains plug before starting the maintenance work at the compressor

 

The  user  is  responsible  for  complying  with  the  location  specific  safety  and mounting  regula-
tions (you can ask an electrician) 

 

In case of device failure the repairs can be carried out only by an electrician or by the WilTec-
repair service

 
 

 

Summary of Contents for AF189

Page 1: ...RTICLE 34205 Read and follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificant ly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...ank you for purchasing this quality product To minimize the risk of injury by means of fire or electric shock we urge that our clients take some basic safety precautions when using this device Please read the operation instructions carefully and make sure you have understood its content Always use a grounded power connection with the appropriate mains voltage You can find the corre sponding mains ...

Page 3: ...evice if the safety ap pliances are damaged or worn out Never override safety regulations Use the device exclusively according to the intended purpose stated in the instructions for use You are responsible for the safety of the working environment If the cable or the plug is damaged due to external influences the cable must not be repaired It has to be replaced with a new one This work can be carr...

Page 4: ... Do not pull the power cable in order to unplug it from the power socket If the compressor is used outdoors only approved extensions may be used Every wire of the extension cable must have at least 1 5 mm2 cross section Do not store the compressor with the plug inserted into the plug Do not allow children or any other people who are not able to handle this device to play or work with it Be very ca...

Page 5: ... by the pressure gauge the operating pressure can be adjusted by the pressure regulator The hose that is included in the supply is air impermeable If the auto stop mode is activated repeat edly switch on off any and all screw fittings and connections should be sealed by a tape made of tef lon Testing of leakage Switch on the compressor and wait until the maximum pressure has built up and the auto ...

Page 6: ...sed only according to the operating instructions Operation o The manometer reports the working pressure of the air tool o Pull up the adjusting knob its clockwise rotation increases the pressure and a counter clockwise rotation reduces the pressure o Rotate the adjusting knob to achieve the right working pressure and fixate it downwards by click ing it into place o Do not rotate the knob against h...

Page 7: ...OR 2 30 AF18 31 PRESSURE SWITCH 1 8 AF18 09 FRONT BODY 1 31 AF18 32 WATER RELEASE NEDDLE 1 9 AF18 10 COUNTERWEIGHT 1 32 AF18 33 CONDENSER 1 10 AF18 11 MANOMETER 1 33 AF18 34 POWER SWITCH 1 11 AF18 12 BEARING 1 34 AF18 35 WIRE 1 12 AF18 13 RETAINIER RING 1 35 AF18 36 RUBBER PAD 4 13 AF18 14 COMPRESSION RING 1 36 AF18 37 HEXAGON NUT 1 14 AF18 17 CYLINDER 1 37 AF18 38 CONNECTOR 2 17 AF18 18 VALVE PLA...

Page 8: ...opean countries with a separate collection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correct disposal of this article you protect the environment and the health of your f...