background image

 

© by WilTec Wildanger Technik GmbH 

 

Item 63132

 

Page 2 

 

http://www.WilTec.de

 

http://www.aoyue.eu  

 

  

 

03 2022

-1

 

http://www.teichtip.de

 

 

The information contained in this document may alter at any time without prior notice. No part of this 
document may be copied or otherwise duplicated without prior written consent. All rights reserved.

 

WilTec Wildanger Technik GmbH cannot be held liable for any possible mistakes in this operating man-
ual, nor in the diagrams and illustrations shown.

 

Although WilTec Wildanger Technik GmbH has made every possible effort to ensure that this operating 
manual is complete, accurate, and up-to-date, errors cannot be ruled out entirely.

 

If you have found an error or wish to suggest an improvement, we look forward to hearing from you.

 

Send us an e-mail to:

 

 

[email protected]

 

 

or use our contact form:

 

 

https://www.wiltec.de/contacts/

 

 

The most recent version of this manual in several languages can be found in our online shop:

 

 

https://www.wiltec.de/docsearch

 

 
 

Our postal address is:

 

 

WilTec Wildanger Technik GmbH

 

Königsbenden 12

 

52249 Eschweiler Germany

 

 

Do you wish to collect your goods? Our address for collection is:

 

 

WilTec Wildanger Technik GmbH

 

Königsbenden 28

 

52249 Eschweiler Germany

 

 

In order to shorten the waiting time and to allow for an easy on-site processing, we kindly ask you to 
contact us briefly beforehand or to place your order via the webshop.

 

 

E-mail: [email protected]

 

Phone: +49 2403 55592–0

 

Fax: +49 2403 55592–15

 

 

To return your goods for exchange, repair, or other purposes, please use the following address. Atten-
tion! To allow for a trouble-free complaint or return, it is important to contact our customer service team 
before returning your goods.

 

 

Retourenabteilung

 

WilTec Wildanger Technik GmbH

 

Königsbenden 28

 

52249 Eschweiler Germany

 

 

E-mail: 

[email protected]

 

Phone: +49 2403 55592–0

 

Fax: (+49 2403 55592–15)

 

 

Summary of Contents for 63132

Page 1: ...y vary depending on model Please read and follow the operating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps and technical data may deviate insignificantly due to continuous further developments ...

Page 2: ...https www wiltec de contacts The most recent version of this manual in several languages can be found in our online shop https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to collect your goods Our address for collection is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler Germany In order to shorten t...

Page 3: ... gas cooker This device is not intended to be used by persons including children with limited physical sensory or mental capabilities or a lack of experience and or knowledge Children should be supervised to ensure that they do not play with the device The gas cooker may only be operated with extreme caution and in perfect condition Safety of use The device may only be used after you have read the...

Page 4: ...ibition severe and even fatal poisoning can result from smoke or carbon monoxide CO formation Children and other unauthorised persons must be kept away from the device Do not wear loose clothing when using the gas cooker Intended use This product is only intended and suitable for private use This product is only intended for use as a heat source for the preparation of food This gas cooker may only...

Page 5: ...lTec Wildanger Technik GmbH Item 63132 Page 5 http www WilTec de http www aoyue eu 03 2022 1 http www teichtip de Scope of delivery and assembly CAUTION Despite great care the components can have sharp edges ...

Page 6: ...quipped with a protective valve Connecting the gas cylinder Make sure that the valve of the gas bottle is closed if necessary close it by turning it clockwise the existing external thread fits all burner controls on the gas cooker are switched off set to off Check the valve connection and regulators for damages and contamination clean them if necessary the hose for damages and obstructions replace...

Page 7: ...fireproof flat solid stable and anti slip surface there are no constructions in the vicinity around 3 m you can observe it during the entire operation The gas cooker may only be stored if it has entirely cooled down and dried off if necessary has been cleaned has been disconnected from the gas cylinder can be stored separately CAUTION Note that storing the device in totally closed rooms or in outs...

Page 8: ...cur as well in case the cooking time is insufficient Maintaining and cleaning DANGER Burning hazard Wait for the product to completely cool down after use Health risk The product is used for food do not clean it with chemicals Cleaning 1 Wait for the product to completely cool down 2 Remove coarse dirt with a brush 3 Clean all surfaces with a slightly damp cloth not under running water 4 Thoroughl...

Page 9: ...d Flame kickback Burner connection blocked Free or clean burner connection Gas escapes on or near the gas cylinder Connection error of pressure re ducer loose connection of pressure re ducer defective worn joint Close the gas valve Remove pressure reducer check condi tion of joint replace if necessary carefully connect pressure re ducer ensure that it is correctly closed Flames do not spread to ot...

Reviews: