Cleaning the air valves

The device should be kept clean in order to allow the air valves to cool the device and its motor.

Lubricating the connections

In order to ensure smooth and proper junctions and to keep o-rings from drying out, the junctions
should be lubricated regularly.

Troubleshooting

Problem

Possible cause

Potential solution

The device does not
start

Device is not connected to
the mains supply

Malfunctioning   socket-out-
let

Fuse has blown

Damaged extension cord

Connect the device

Try another socket-outlet

Replace the fuse

Disconnect other devices

Replace the extension cord or try
operate the device without

Pressure   fluctu-
ations

Pump draws air

Valves are dirty, blocked or
worn 

Insufficient water supply

Pump seal is worn

Check   impermeability   of   hoses
and connections 

Increase   the   water   pressure,
check   for   blockage   and/or   ex-
change the hose

Consult a qualified expert

The device stops its
operation

Fuse has blown

Incorrect line voltage

Overheating   protection   is
active

Partially clogged nozzle

Replace the fuse

Disconnect other devices

Check if voltage conforms to the
nameplate of the device

Device needs to cool down for 5 
minutes

Clean the nozzle with a needle

Fuse has blown

Fuse is too small

Increase of amperage 

Replace with a sufficient fuse

Try   operating   without   extension
cord

Device sputters

Air inside the hose/pump

Insufficient water supply

Partially blocked water jet

Water filter is clogged

Buckled hose

Pull the trigger to release air until
the air has been drained

Increase   the   water   pressure,
check   for   blockage   and/or   ex-
change the hose

Clean the nozzle with a needle

Clean the filter

Unfold the hose

Device turns on and
off on its own

Fuse or pump control mal-
functions

Insufficient water supply

Consult a qualified expert

Connect to sufficient water supply

Device   is   running,
but   no   water   is   re-
leased

Dirty or clogged water filter

Blocked nozzle

Clean the water filter

Clean the nozzle with a needle

© by WilTec Wildanger Technik GmbH 

Item 62571

Page 11 

http://www.WilTec.de
http://www.aoyue.eu

 

11 2020

-1

http://www.teichtip.de

Summary of Contents for 62571

Page 1: ...nstructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignific antly...

Page 2: ...nguages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH K nigsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our...

Page 3: ...If the power cord should be damaged do not try to repair it A damaged power cord must not be repaired and has to be replaced by a qualified electrician Warning This device can be dangerous if used in...

Page 4: ...essories of equal quality authorised by the manufacturer Warning Inappropriately secured damaged or insufficiently long extension cords can be dan gerous Cables and cable reels always have to be unwou...

Page 5: ...9 Pressure hose connector 2 Pressure hose intake 10 Machine frame 3 Water hose connector 11 Power cord 4 Short pressure hose 12 Power plug 5 Pressure hose 13 Water supply hose 6 Hose reel 14 Water tap...

Page 6: ...ated again The cooling process should thereby only take a few minutes Operation Water hose connection Screw the water inlet coupling to the water inlet Note Always place the inlet filter inside the in...

Page 7: ...plate in the technical specifications Always use an enhanced hose not included in the scope of delivery with a standard connection outer diameter 16 mm inner diameter 12 mm and a max imum length of 25...

Page 8: ...on If the pressure washer is not in use for 5 or more minutes the device has to be turned off 1 Use the power switch 7 and set it to the 0 position in order to stop the device 2 Disconnect the device...

Page 9: ...Setup by WilTec Wildanger Technik GmbH Item 62571 Page 9 http www WilTec de http www aoyue eu 11 2020 1 http www teichtip de...

Page 10: ...d properly dry them Store them in their respective holders Warning Never use the device in a freezing environment or after it has been exposed to such an en vironment and low temperatures before In th...

Page 11: ...n Incorrect line voltage Overheating protection is active Partially clogged nozzle Replace the fuse Disconnect other devices Check if voltage conforms to the nameplate of the device Device needs to co...

Page 12: ...orm aux dierectives europ ennes 2006 42 EC Es ist nach folgenden harmonisierten Normen gepr ft worden It has been tested with the following harmonised standards Il a t test partir des norms harmonis e...

Page 13: ...ts out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the corr...