WilTec 61958 Operation Manual Download Page 2

The information contained in this document may alter at any time without previous notice. It is prohib-
ited to copy or spread any parts of this document in any way without prior written allowance. All rights
reserved.
The WilTec Wildanger Technik GmbH cannot be held accountable for any possible mistakes in this
operating manual, nor in the diagrams and figures shown.
Even though, the WilTec Wildanger Technik GmbH has undergone biggest possible efforts to ensure
that the operating manual is complete, faultless and up to date, mistakes cannot be entirely avoided.
If you should find a mistake or wish to make a suggestion for improvement, we look forward to hearing
from you.

Send an e-mail to:

[email protected]

or use our contact form:

https://www.wiltec.de/contacts/

The most recent version of this manual in various languages can be found in our online shop via:

https://www.wiltec.de/docsearch

Our postal address is:

WilTec Wildanger Technik GmbH
Königsbenden 12
52249 Eschweiler
Germany

Do you wish to pick goods up? Our pick-up address is:

WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
Germany

To shorten the waiting time and allow for a rapid on-site transaction, we ask you to call us previously
or placing your order via the webshop.

E-mail: [email protected]
Tel:+49 2403 55592-0
Fax: +49 2403 55592-15

To return orders for exchange, repair or for other purposes, please use the following address. Atten -
tion! To allow for a smooth execution of your complaint or return, it is important to contact our cus -
tomer service team before returning the goods.

Returns Department
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler

E-mail: 

[email protected]

Tel:+49 2403 55592-0
Fax: +49 2403 55592-15

© by WilTec Wildanger Technik GmbH 

Item 61958

Page 2

http://www.WilTec.de
http://www.aoyue.eu  

  

02 2021

-1

http://www.teichtip.de

Summary of Contents for 61958

Page 1: ...g instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignific antly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...anguages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler Germany To shorten the waiting time and allow for a rapid on site transaction we ask you to call us previously or pla...

Page 3: ...d tilt the compressor to drain the accumulated water To avoid danger the compressed air jet must never be directed at persons or animals To avoid combustion never touch the pipes engine or any other hot components of the com pressor Do not make any changes to the compressor Contact the manufacturer or an authorized ser vice partner for all repairs Unauthorized modifications may affect compressor p...

Page 4: ...out any repair inspection maintenance cleaning or component replacement work the compressor must be disconnected from the mains supply and the pressure released from the boiler Never use the compressor near water or in a humid environment Always wear protective glasses or eye protection Never point the compressed air jet at your own body or at other persons Never operate the compressor unless all ...

Page 5: ...his can lead to a reduced service life of the compressed air hose Ensure that the intake air is clean dry and dust free Do not place the compressor in a wet or humid room Description This compressor impresses with its new design and excellent operation It has a very compact con struction good appearance low weight easy handling good safety and low noise level It can be used for machines air brushe...

Page 6: ...4 Pressure regulator A Discharge pressure 5 Pressure gauge B Tank pressure 6 Check valve C Safety valve 7 Drain cock D Discharge valve 2 8 Wheel E Discharge valve 1 9 Discharge tube F Pressure regulator by WilTec Wildanger Technik GmbH Item 61958 Page 6 http www WilTec de http www aoyue eu 02 2021 1 http www teichtip de ...

Page 7: ...compressor is secured by a pressure switch As soon as the max boiler pressure is reached it switches off automatically As soon as the pressure has fallen below the minimum rate it switches on again This pressure setting was made ex factory and must not be changed As soon as the engine switches off the compressed air in the discharge pipe should be released by the release valve under the switch Thi...

Page 8: ...ssor with water jets or flammable liquids Do not place any flammable objects near the compressor Set the push button and power button to OFF when pauses are made or the unit is not in use Never aim the air jet at people or animals Never transport the compressor as long as there is pressure in the tank Make sure that some parts of the compressor head pressure hoses can become very hot Do not touch ...

Page 9: ...get into the compressor Check and remove Piston hits the valve Replace cylinder gasket Moving parts worn out Replace cylinder gasket Pressure too low or unloading capacity low Motor runs too slowly Check and repair Air filter dirty Clean or replace Safety valve leaking Check or change Drain valve leaking Check or repair Gasket damaged Check and change Valve blocked Remove and clean Worn piston rin...

Page 10: ...Exploded view by WilTec Wildanger Technik GmbH Item 61958 Page 10 http www WilTec de http www aoyue eu 02 2021 1 http www teichtip de ...

Page 11: ...48 Washer 8 mm 2 17 Oil cover 1 49 Washer 10 mm 2 18 Oil level indicator seal 1 50 Sleeve 10 mm 2 19 Oil level indicator 1 51 Wheel 2 20 Screw M6 10 1 52 Bolt screw 10 mm 2 21 O clip 5 6 1 8 1 53 Pedestal 1 22 Rubber gasket 1 54 Drain valve 1 23 Piston rod 1 55 Tank 1 24 Allen screw M8 22 left 1 56 Screwing Rp 2 25 Crankshaft 1 57 Nut Rp 1 26 Crankcase 1 58 Pressure regulator 1 27 Protective ring ...

Page 12: ...nts out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correct disposal of this art icle you protect the environment and the health of your fellow men Environment and health are threatened by inappropriate disposal Materials recycling helps reduce the consum...

Reviews: