WilTec 50752 Operation Manual Download Page 1

  

© by WilTec Wildanger Technik GmbH  

 

Seite 1  

http://www.wiltec.info  

 
 

 

Operation Manual 

Garden Pump 

 

ARTICLE 50752 

 

 

 

 

 

 

 
Read and follow the operating instructions and safety information before using for the first time.  
 

Technical changes reserved! 

Due  to  further  developments,  illustrations,  functioning  steps  and  technical  data  can  differ 
insignificantly. 

Updating the documentation

 

If you have suggestions for improvement or have found any irregularities please contact us. 

Summary of Contents for 50752

Page 1: ...operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...es of water garden ponds or swimming ponds and their surrounding areas only with fault current protection switch with a triggering nominal current up to 30mA according to VDE 0100 Article 702 and 738 The device is not suitable for use in swimming pools paddling pools and other bodies of water in which during operation people or animals linger The operation of the device during the stay of people a...

Page 3: ...ury Keep the instructions and the safety guidelines in a safe place in case you need them in the future Stability The max temperature of the conveyed water should not exceed 35 C in permanent operation The conveyance of explosive flammable or gassing fluids is not allowed The conveyance of aggressive fluids acids bases etc as well as of abrasive liquids for example sand must be avoided To avoid da...

Page 4: ...uction of water due to air intake Avoid sucking in foreign particles sand etc and if necessary install a prefilter Pressure line connection The pressure line should be at least 3 4 must be connected directly or via a thread nipple to the pressure line connector 1 internal thread of the pump With the suitable screw joints a 1 2 pressure hose can be used Correspondingly the pump output is reduced du...

Page 5: ...ocked connect the pressure line to the water line and remove the suction hose Open the water line Turn on the pump for sevaral times for approx two seconds This way blockages can be cleared in most cases Pump s Dysfunctions No engine running Cause Remedy No supply voltage Check the power supply Pump wheel is blocked Thermal controller has shut down Dismantle the pump and clean it Parts Description...

Page 6: ...ion valve more deeply Pump efficiency is reduced due to harmful substances Clean the pump and replace the wear part Thermal controller shuts down the pump Cause Remedy Engine overload high friction with other foreign particles Dismantle the pump and clean it prevent the suction of foreign particles Filter Attention The pump must not run dry Pump control Pressure switch EDWC2001 The pressure switch...

Page 7: ...e to lack of water protection against dry running press Restart to start the unit again 2 The middle 2nd LED blinks the pump is switched on 3 The lower 3rd LED blinks the switch has voltage 4 Restart Reset restart button Possible dysfunctions and their solutions Dysfunction Dysfunction of the unit Dysfunction outside the unit The pump won t start Circuit board is damaged Missing voltage Pump is de...

Page 8: ...parate collection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal household waste but must be disposed to a recycling collection point for electronic and electrical waste equipment By contributing to the correct disposal of this article you protect the environment and the health of your fellow men Environment and he...

Page 9: ...perly used the above mentioned model fulfils the basic requirements and the guidelines complying with the 2004 108 EC When evaluating the product according to the EU demands the following standards were applied EN 55014 1 2006 EN 55014 2 1997 A1 EN61000 3 2 2006 EN61000 3 3 1995 A1 A2 If the product is changed this declaration loses its validity Eschweiler 13 Oktober 2009 _________________________...

Reviews: