Introduction

 

 
Thank you for purchasing this quality product.

 To minimize the risk of injury we urge that our cli-

ents  take  some  basic  safety  precautions  when  using  this  device.  Please  read  the  operation 
instructions carefully and make sure you have understood its content.

 

Keep these operation instructions safe. 
 

 Attention: 

The  device  is  not  intended  for  use  by  persons  (including  children)  with  impaired  or  limited  physical, 
sensory and mental abilities or lack of experience and/or real knowledge, unless they are supervised 
by a person responsible for their safety or you follow the instructions made by this person how to use 
the device correctly. 
 
Children should be supervised to make sure that they do not play with the device. 
 
 

Safety regulations

 

 

 

Run a visual inspection of the device before every use. Do not use the device if safety appli-
ances are damaged or worn out. Never override safety regulations. 

 

Use  the  device  exclusively  according  to  the  intended  purpose  stated  in  the  instructions  for 
use. 

 

You are responsible for the safety of the working environment. 

 

If the cable or the plug is damaged due to external influences the cable must not be repaired! 
It has to be replaced with a new one. This work can be carried out only by an electrician. 

 

The voltage indicated on the type plate of the device of 230 V AC has to correspond to the ex-
istent mains voltage. 

 

Never lift, carry, or fix the device by using the power cable. 

 

Make sure that the electrical plug connection is placed in a flood-proof area and is protected 
from moisture. 

 

Disconnect the mains plug before the maintenance work. 

 

Avoid exposing the diesel pump to direct water jets or rain. 

 

The operator is responsible for compliance with location-specific safety and installation regula-
tions. If necessary, ask a qualified electrician. 

 

Consequential damage arising from flooded rooms caused by dysfunctions of the device must 
be avoided by means of appropriate measures (e.g., by installing an alarm system, a reserve 
pump). 

 

In case of malfunction, the repair work can be carried out only by a qualified electrician. 

 

The device must not run dry or with a completely closed intake port. The manufacturer’s guar-
antee is no longer valid if the damage is caused by dry running. 

 
 

 Attention: 

Read carefully all the safety guidelines and the instructions. 

Non-compliance with the safety rules 

and regulations can lead to an electric shock, fire and/or serious injury. 
Keep the instructions and the safety guidelines in a safe place in case you need them in the future. 
 
 

Resistance

 

 

 

The temperature of the conveyed liquid should not 35 

 in permanent operation. 

 

The  pump  must  not  convey  aggressive  fluids  (acids,  alkali,  etc.)  or  fluids  with  abrasive  sub-
stance (sand). It must 

NOT

 pump water or easy flammable liquids (petrol). 

 

 

Summary of Contents for 50588

Page 1: ...ing on model Read and follow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificant ly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ... service wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Esc...

Page 3: ...carried out only by an electrician The voltage indicated on the type plate of the device of 230 V AC has to correspond to the ex istent mains voltage Never lift carry or fix the device by using the power cable Make sure that the electrical plug connection is placed in a flood proof area and is protected from moisture Disconnect the mains plug before the maintenance work Avoid exposing the diesel p...

Page 4: ...s up if the engine is started The engine is protected against overloading or blocking by means of a built in motor protec tion In case of overheating the pump is turned off automatically due to the overheat protection and after its cooling the pump is automatically started Suction pipeline Connect a suction hose plastic hose minimum with spiral reinforcement directly or with a threaded fitting to ...

Page 5: ...th the diesel or heating oil at the pressure port During the suction process the shut off devices pump nozzle and valve in the pressure line must be completely open so that the air existing in the suction line can escape freely Depending on the suction lift and air volume in the suction line the first suction operation can take approx 0 5 min 5 min By longer suction times the medium to be pumped s...

Page 6: ...p Engine not running Consult a professional electrician Pump does not suck in Cause Corrections of malfunctions Suction valve not inside the pumped medium Bring the suction valve in the pumped medium Pump room without pump medium Fill in pump medium in suction nozzle Air in suction line Check if suction line is well sealed Suction valve untight Clean suction valve Suction strainer valve blocked Cl...

Page 7: ...ther European countries with a separate collection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correct disposal of this article you protect the environment and the health o...