Operation:

 

 

The pressure gauge reports the air tool working pressure.

 

 

Pull up the adjusting knob; its being clockwise rotated increases the pressure, a counter-clock-
wise rotation reduces the pressure.

 

 

Rotate the adjusting knob to achieve the right working pressure and lock it downwards by click-
ing it into place.

 

 

Do not rotate the knob against high resistance. If necessary, the height and the position of the 
of the knob can vary slightly.

 

 

For emptying the condensed water collector use the water drain plug.

 

 
 

Exploded view and parts list

 

 

 

 

Name

 

Qty.

 

 

Name

 

Qty.

 

1

 

Screw

 

8

 

26

 

O-ring

 

1

 

2

 

Pipe nut

 

2

 

27

 

Cylinder head

 

1

 

3

 

Block

 

1

 

28

 

Cap screw

 

4

 

4

 

Rear body

 

1

 

29

 

Filter valve

 

1

 

5

 

Screw

 

4

 

30

 

Handle

 

1

 

6

 

Stationary motor

 

1

 

31

 

Pressure switch

 

1

 

7

 

Bearing

 

2

 

32

 

Water drain valve

 

1

 

8

 

Rotary motor

 

1

 

33

 

Condenser

 

1

 

9

 

Front body

 

1

 

34

 

Power switch

 

1

 

10

 

Counterweight

 

1

 

35

 

Wire

 

1

 

11

 

Pressure gauge

 

1

 

36

 

Rubber pad

 

4

 

Summary of Contents for 34244

Page 1: ...ating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...ervice wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschw...

Page 3: ...ly be carried out by an electrician The 230 V alternating voltage indicated on the type plate of the device must correspond to the existent mains voltage Never lift carry or fix the device by using the power cable Make sure that the electrical plug connection is protected from flood and moisture Disconnect the mains plug before starting the maintenance work at the compressor The user is responsibl...

Page 4: ...tightened Do not use the compressor if it is damaged If the compressor generates unusual noises and strong vibrations or if other unusual signs occur that indicate some damage you should turn off the compressor immediately For repairs please use only original spare parts Do not make any technical modifications to the compressor In case you cannot eliminate the malfunction hand over the device to a...

Page 5: ... all kinds of nozzles from 0 2 to 1 0 mm Notes The compressor has a 9 51 mm outlet male thread which can be effortlessly changed to The matching adapter is not included in the supply When the compressor is connected by the hose to the airbrush gun the compressor can be connected to the mains and be switched on The maximum pressure is displayed by the pressure gauge the operating pressure can be ad...

Page 6: ... possible in order to avoid any impact on the capacity and efficiency of the compressor A leak causes the auto stop and auto start function to be carried out permanently Difference between maximum and operating pressure The maximum pressure is the highest possible pressure a compressor can generate Once the maximum pressure has been reached the compressor switches off auto stop As soon as the pres...

Page 7: ...y click ing it into place Do not rotate the knob against high resistance If necessary the height and the position of the of the knob can vary slightly For emptying the condensed water collector use the water drain plug Exploded view and parts list Name Qty Name Qty 1 Screw 8 26 O ring 1 2 Pipe nut 2 27 Cylinder head 1 3 Block 1 28 Cap screw 4 4 Rear body 1 29 Filter valve 1 5 Screw 4 30 Handle 1 6...

Page 8: ...ner ring 1 38 Connector 2 14 Compression ring 1 39 Connecting ring 1 15 Pipe 1 40 Adaptor 1 16 Adaptor 1 41 Screw 1 17 Cylinder 1 42 Tank 1 18 Valve plate 2 43 Drain valve 1 19 O ring 1 44 Safety valve 1 20 Screw 1 45 Adaptor 1 21 Front gasket 1 46 Fan 1 22 Front cover 1 47 Case 1 23 Filter 1 48 Cover 1 24 O Ring 1 49 Base 1 25 Cylinder block 1 50 Fan cap 1 ...

Page 9: ...European countries with a separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equipment By contributing to the correct disposal of this article you protect the environment and the health of you...

Reviews: