© by WilTec Wildanger Technik GmbH
Item 34244
Page 7
02 2022
-1
Operation:
•
The pressure gauge reports the air tool working pressure.
•
Pull up the adjusting knob; its being clockwise rotated increases the pressure, a counter-clock-
wise rotation reduces the pressure.
•
Rotate the adjusting knob to achieve the right working pressure and lock it downwards by click-
ing it into place.
•
Do not rotate the knob against high resistance. If necessary, the height and the position of the
of the knob can vary slightly.
•
For emptying the condensed water collector use the water drain plug.
Exploded view and parts list
№
Name
Qty.
№
Name
Qty.
1
Screw
8
26
O-ring
1
2
Pipe nut
2
27
Cylinder head
1
3
Block
1
28
Cap screw
4
4
Rear body
1
29
Filter valve
1
5
Screw
4
30
Handle
1
6
Stationary motor
1
31
Pressure switch
1
7
Bearing
2
32
Water drain valve
1
8
Rotary motor
1
33
Condenser
1
9
Front body
1
34
Power switch
1
10
Counterweight
1
35
Wire
1
11
Pressure gauge
1
36
Rubber pad
4