en
Installation and operating instructions • Wilo-Yonos MAXO/-D/-Z • Ed.01/2022-08
17
Specification
Value
Emissions sound-pressure level
< 52 dB(A)
Energy efficiency index (EEI)
See rating plate
Temperature class
TF110 (see IEC 60335-2-51)
Pollution degree
2 (IEC 60664-1)
Max. permissible operating pressure
PN 6/10
For further instructions see rating plate and catalogue.
Technical data Yonos MAXO-Z
Specification
Value
Permissible fluid temperature
0 °C ... +80 °C (for short periods (2 h): +110 °C)
Permissible ambient temperature
0 °C ... +40 °C
Maximum relative humidity
≤ 95 %
Mains voltage
1~ 230 V +/-10 % 50/60 Hz
Residual current ∆I
≤ 3.5 mA
Electromagnetic compatibility
Interference emission in acc. with:
EN 61800-3:2004+A1:2012/residential environment
(C1)
Interference immunity in acc. with:
EN 61800-3:2004+A1:2012/industrial environment
(C2)
Emissions sound-pressure level
< 52 dB(A)
Energy efficiency index (EEI)
See rating plate
Temperature class
TF80 (see IEC 60335-2-51)
Pollution degree
2 (IEC 60664-1)
Max. permissible operating pressure
PN 6/10
For further instructions see rating plate and catalogue.
5.4
Min. inlet pressure
Nominal diameter
Fluid temperature
-20 °C to +50 °C
0 °C to +50 °C
1)
up to +95 °C
up to +110 °C
G 1½
0.3 bar
1.0 bar
1.6 bar
G 2
0.3 bar
1.0 bar
1.6 bar
DN 32
0.3 bar
1.0 bar
1.6 bar
DN 40
0.5 bar
1.2 bar
1.8 bar