Technical data

When ordering spare parts, make sure to state all the information 
given on the pump and motor rating plates.

Fluids

If water/glycol mixtures with up to 40% glycol (or fluids with a differ-
ent velocity to pure water) are used, the pump data must be corrected 
to match the higher viscosity, regardless of the percentage mixture 
relationship and the fluid temperature. The motor power must also be 
adjusted if necessary.

• Only use mixtures with corrosion inhibitors. The respective manufac-

turer's instructions are to be observed.

• The fluid must be sediment-free.
• Wilo's approval must be obtained for the use of other fluids.

NOTE
Always read and follow the material safety data sheet for the fluid 
being pumped.

5.3

Scope of delivery

• IPH-W/O  pump
• Installation and operating instructions
• Counter flange and seals

5.4

Accessories

Accessories must be ordered separately:

• PTC  thermistor  tripping unit for switch cabinet installation

For a detailed list, consult the catalogue/price list.

Property

Value

Remarks

Rated speed

2900 or 1450 rpm

Nominal diameters DN

IPH-O:  20 to 80
IPH-W:  20 to 80

Permissible min./max. fluid temperature

IPH-O: +20 °C to +350 °C
IPH-W: -10 °C to +210 °C

Max. ambient temperature

+40 °C

Maximum permissible operating pressure IPH-O:   9 bar at max. +210 °C

IPH-W: 23 bar at max. +350 °C

Insulation class

F

Protection class

IP 55

Pipe and pressure measurement connec-
tions

Tongue and groove flange PN25 
(in accordance with DIN EN 1092-1) 

Standard version

Approved fluids

Heating water according to VDI 2035
Water/glycol mixture up to 40 Vol.-%

Standard version

Heat transfer oil

Standard version

Electrical connection

3~400 V, 50 Hz

Standard version

3~230 V, 50 Hz

Alternative application for stand-
ard version (no additional charge)

Motor special version

Special voltage/frequency 
(on request)

Special version or auxiliary equip-
ment (at additional charge)

Motor protection

Required onsite

Standard version

Speed control

Wilo control devices

Standard version

Summary of Contents for VeroLine IPH Series

Page 1: ...IPH O IPH W Pioneering for You 2 140 983 Ed 01 2013 10 Wilo de Einbau und Betriebsanleitung en Installation and operating instructions fr Notice de montage et de mise en service nl Inbouw en bediening...

Page 2: ...Fig 1 Fig 2 Fig 3...

Page 3: ...Fig 4 1 2 3 1 2 3 3 6 3 5 2 2 1 3 3 2 3 3 3 4 6 3 6 2 6 1 1 2 2 2 2 3 3 2 3 3 3 4 7 3 5 6 8 9 10 4 1 1 1 2 1 2 2 2 1 2 4 2 2 2 3...

Page 4: ......

Page 5: ...de Einbau und Betriebsanleitung 3 gb Installation and operating instructions 19 fr Notice de montage et de mise en service 35 nl Inbouw en bedieningsvoorschriften 51...

Page 6: ...erim storage 21 3 1 Shipping 21 3 2 Transport for installation dismantling purposes 21 4 Intended use 22 5 Product information 22 5 1 Type key 22 5 2 Technical data 23 5 3 Scope of delivery 23 5 4 Acc...

Page 7: ...ting instructions on product personnel safety are not observed this declaration loses its validity 2 Safety These operating instructions contain basic information which must be adhered to during insta...

Page 8: ...ng and safety regulations of the operator are to be complied with 2 5 Safety instructions for the operator This appliance is not intended for use by persons including children with reduced physical se...

Page 9: ...l under or exceed those specified in the catalogue data sheet 3 Transport and interim storage 3 1 Shipping The pump is enclosed in a box or lashed to a pallet ex works and is pro tected against dirt a...

Page 10: ...its Contraindications Typical installation locations are technical rooms within the building with other domestic installations Installing the device directly in other used rooms residential and work r...

Page 11: ...cessories must be ordered separately PTC thermistor tripping unit for switch cabinet installation For a detailed list consult the catalogue price list Property Value Remarks Rated speed 2900 or 1450 r...

Page 12: ...ury Failure to install safety devices on the motor terminal box or on the coupling can cause electrical shock or contact with rotating parts potentially resulting in life threatening injuries Before c...

Page 13: ...hich accumulates in the lantern can be discharged spe cifically via the existing holes The lantern has an opening on the underside which allows a drain pipe for condensation water to be con nected The...

Page 14: ...3 mm in accordance with VDE 0730 Part 1 in Germany The connection line is to be installed in such a way that it cannot under any circumstances come into contact with the pipe and or the pump and motor...

Page 15: ...oupling covers that were removed must be reinstalled Keep a safe distance during commissioning Always wear protective clothing protective gloves and protective goggles when working WARNING Risk of bur...

Page 16: ...a minimum volume flow of 10 15 of the pump s rated volume flow must be guaranteed NOTE When pumping out of a tank ensure that the liquid level is always high enough above the suction port of the pump...

Page 17: ...system pressures allow the pump to cool down before all work Always wear protective clothing protective gloves and protective goggles when working 9 1 Mechanical seal The mechanical seal is maintenan...

Page 18: ...ctions in conjunction with the work described in the following Observe the screw tightening torque for the thread type see section Screw tightening torques on page 14 NOTE If you replace the mechanica...

Page 19: ...supply remove cause of blockage if motor blocked overhaul replace motor motor impeller unit Cable terminal loose Tighten all terminal screws Fuses defective Check fuses replace faulty fuses Motor dama...

Page 20: ...2 Disc 2 3 Nut 3 1 Cooling housing 3 2 Circlip 3 3 Retaining ring 3 4 O ring 3 5 O ring 3 6 Screw 4 Motor 5 Mechanical seal set Nut 6 Intermediate piece set with Locking disc 1 2 Flat gasket 2 2 Disc...

Page 21: ...equires the product to be drained and cleaned Lubricants must be collected The pump components are to be sepa rated according to material metal plastic electronics 1 Use public or private disposal org...

Page 22: ......

Page 23: ...rective 2006 95 EC are realized according annex I No 1 5 1 of the EC Machinery directive 2006 42 EC Les objectifs protection de la directive basse tension 2006 95 CE sont respect es conform ment appen...

Page 24: ...o strojn ch za zen ch 2006 42 ES Przestrzegane s cele ochrony dyrektywy niskonapi ciowej zgodnie z za cznikiem I nr 1 5 1 dyrektywy maszynowej 2006 42 WE I 1 5 1 2006 42 G Sm rnice o elektromagnetick...

Page 25: ...O Pumps Indonesia Jakarta Selatan 12140 T 62 21 7247676 Ireland WILO Ireland F T 353 61 227566 Italy Borromeo Milano T 39 25538351 Kazakhstan WILO Central Asia 050002 Almaty T 7 727 2785961 F Korea z...

Page 26: ...Pioneering for You WILO SE Nortkirchenstra e 100 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Reviews: