Troubleshooting
E:\shares\Baprod\BA\subtec_m\general\us\troubleshooting.fm
9-3
Fault: The machine does
not run smoothly and is
noisy
Fault: Mechanical shaft
seal leaks, sealing cham-
ber monitor reports fault
and switches the ma-
chine off
(Sealing chamber monitoring is optional, and is not available for all types. For details on this, see the
order confirmation or the electrical terminal connection plan.)
Excessive decrease in the water table during
operation
Check the supply and capacity of the system,
and inspect the level control settings and
function
Cause
Remedy
Table 9-4: The machine runs, but not at the stated operating levels
Cause
Remedy
Machine is running in an impermissable oper-
ation range
Check the operational data of the machine
and correct if necessary and/or adjust the
operating conditions
The suction port, strainer and/or impeller/pro-
peller is blocked
Clean the suction port, strainer and/or impel-
ler/propeller
The impeller is impeded
Switch off the machine, secure it against
being switched on again and free the impeller
Inadmissible levels of gas in the pumped liquid
Contact the factory
Two-phase operation
Have a specialist inspect the connection and
correct it as necessary
Incorrect direction of rotation
Replace 2 phases on the mains supply
Signs of wear
Replace worn parts
Defective motor bearing
Contact the factory
The machine is installed with mechanical
strain
Check the installation, use rubber spacers if
necessary
Table 9-5: The machine does not run smoothly and is noisy
Cause
Remedy
Condensation build-up due to lengthy stor-
age and/or temperature fluctuation
Operate the machine briefly (max. 5min.)
without sealing chamber monitoring
Expansion tank (optional for polder pumps) is
too high
Install the expansion tank no more than 10m
above the top edge of the suction port
Increased leakage when running in new
mechanical shaft seals
Change the oil
Defective sealing chamber cables
Replace the moisture sensors
Mechanical shaft seal is defective
Replace the mechanical shaft seal after con-
tacting the factory
Table 9-6: Mechanical shaft seal leaks, sealing chamber monitor reports fault and switches the machine off