background image

Installation and operating instructions

WILO_IOM_ICL_1219

Wilo-Cronoline ICL

Inline Close-Coupled Pumps 

Summary of Contents for Cronoline ICL

Page 1: ...Installation and operating instructions WILO_IOM_ICL_1219 Wilo Cronoline ICL Inline Close Coupled Pumps...

Page 2: ...Performance Regulation 6 Transport and Shipping 6 Mechanical Installation 7 Connect Condensate Drain 7 Electrical Connection 8 Fill and Ventilate 8 Check Direction of Rotation 9 Operation 9 Maintenanc...

Page 3: ...pping NPT 3 Air Vent 1 8 NPT 4 Lantern 5 Shaft 6 Motor 7 Cover plate Bolt 8 Condensate Drain Connection 9 Motor Frame Bolt 10 Lantern O ring 11 Mechanical Seal 12 Impeller 13 Impeller Belleville Washe...

Page 4: ...ent 1 8 NPT 5 Shaft 6 Motor 7 Cover plate Bolt 8 Condensate Drain Connection 9 Motor Frame Bolt 10 Lantern O ring 11 Mechanical Seal 12 Impeller 13 Impeller Keys 14 Fender Washer 15 Split Lock Washer...

Page 5: ...fications may be made to the pump Use only original spare parts Electrical Power Supply Working with electrical current could cause serious risk of bodily injury therefore 3 2 1 6 2 1 7 3 1 i ii iii i...

Page 6: ...eal to fail Note For additional data see type plate product information sheet or Wilo catalog Pump housing and lantern Cast Iron Class 30 ASTM A48 Ductile Iron ASTM A536 Impeller Bronze CC480K GS Pump...

Page 7: ...ue to high deadweight The pump itself and pump components may have a very high deadweight There is a risk of potentially fatal impact and crushing caused by falling parts Always use suitable lifting e...

Page 8: ...age Never operate the pump with incorrect voltage This could damage the motor 6 7 Connect grounding cable Install motor control cabling overload protection mains circuit breaker and accessories in acc...

Page 9: ...n by briefly turning it on The direction of rotation is correct if the fan or other visibly rotating parts of the pump are rotating in the direction of the arrow 2 On three phase only if the direction...

Page 10: ...screws on motor flange using torquewrench Torque L Page 11 Press new mechanical seal onto the shaft and into the lantern Use a small amount of approved polymer lubricant and press stationary section o...

Page 11: ...he pump Never operate a pump that is not correctly assembled This can damage the pump Torque 10 Location Material SAE Grade Diameter inches ft lb Nm Impeller Shaft Stainless steel 3 8 22 30 1 2 44 60...

Page 12: ...bi ent temperature Prevent overloads caused by high ambient tem peratures Tripped PTC relay Check motor and fan cover for dirt dust accu mulation and clean if necessary Check ambient temperature and i...

Reviews: