PARTS & LABOUR WARRANTY POLICY - UK ONLY

Our warranty applies to equipment manufactured 

by Williams Refrigeration and equipment bearing the 

Williams name plate and serial number identification 

tag.
We undertake, in conjunction with the supplying 

agent, distributor or representative, to repair free 

of charge during our standard business hours 

any such piece of equipment or part thereof used 

which is found to be faulty in either materials or 

workmanship subject to the further conditions 

below:-

WARRANTY TERMS AND PRODUCTS 

COVERED

We offer 

a 24 months Warranty

 from our original 

date of sale with the following Williams equipment:

1.  Garnet / Zircon / Jade / Amber (stainless) / Mobile 

Heated/ Mobile Refrigerated.

2.  Reach-in Blast Chillers / Reach-in Blast Chiller 

Freezers / Blast Chiller WTBC70.

3.  Opal / Emerald / Onyx / Aztra / Salad Counters / 

UBC / Chef’s Drawers / MaxiPrep Station.

4.  Crystal Bakery Cabinets and Counters.
5.  Meat Ageing Refrigerator.

We offer a 

12 months Warranty

 from our original 

date of sale for all other Williams equipment 

including:

1.  All Modular Products (including coldrooms).
2.  Remote Systems.
3.  Bottle Coolers.
4.  GEM Multidecks (included heated) and 

merchandiser cases.

5.  GEM product range.
6.  Bottle Well / Meat Freezer Well.
7.  Thermowell.
8.  Non standard and other products.
9.  Front of House display cases.
10. White Goods.

WARRANTY TERMS

Our warranty is offered where the equipment has 

been installed correctly and has not been subject to 

misuse or abuse and is functioning correctly.
The equipment was purchased by the authorised 

supplying distributor direct from Williams 

Refrigeration and not through a wholesaler or other 

supplier whose warranty terms may be different.
The Warranty Policy shall be non-transferable.
Replacement of defective equipment can only be 

made with the approval of Williams Refrigeration.
Any repair under warranty will only be carried out 

with the product in its position of operation or in a 

suitable location on the customer’s premises. If the 

product has to be removed for security or any other 

reason, this will be subject to additional charge (may 

include hydrocarbon charged equipment).
Warranty work will be covered by Williams 

Refrigeration or by one of its appointed service 

agents between the hours of 8.00am and 5.00pm 

Monday to Friday. Any works undertaken outside of 

these hours are chargeable.

CLAIMS PROCEDURE

If a customer wishes to make a claim under the 

terms of this warranty, the following procedure 

should be observed:

1.  Contact the supplying agent, representative or 

distributor.

2.  Quote the equipment model, serial number and 

date of installation. The serial number is located 

on the product identification plate inside the 

cabinet, modular product door frame or similar 

location. It is recommended that operators 

should also record the serial number on the 

operating instruction booklet supplied with the 

product.

3.  Contents risk and insurance responsibility 

remains at all times with the customer.

EXCEPTIONS TO STANDARD WARRANTIES

1.  The Standard warranty applies to equipment 

located in Mainland GB only and excludes 

locations subject to restricted or secure 

access,offshore and marine applications. 

Additional time and travel charges may be 

applied to the following locations – Isle of Wight, 

Channel Islands, Isle of Man, Northern Ireland 

and Scottish Isles.

WARRANTY

Summary of Contents for J1BC

Page 1: ...lemented correctly the optimum performance and reliability of your equipment should be maintained We assume the installer user and service provider are appropriately trained skilled and competent to p...

Page 2: ...nd the replacement of parts is required the equipment must be safely disconnected and isolated from the power supply using a lock off system at the isolation device It is advised that the electrical s...

Page 3: ...range of Modular Blast Chillers Chiller Freezers and Freezers are designed to blast chill freeze products WMBC 90 C 194 F 3 C 37 F in 90 minutes or less WMBCF 90 C 194 F 3 C 37 F in 90 minutes or less...

Page 4: ...the cabinet top and the ceiling for engineer access and ventilation For all other cabinets please ensure a minimum clearance of 50mm is provided around the unit to ensure efficient and effective perfo...

Page 5: ...ingle phase and come fitted with a moulded plug for safety and must be earthed We recommend that should the plug or cable fail contact Williams Spares Office for a replacement part WBC WBCF30 40 are s...

Page 6: ...ntainers insulate the food from the cold air When chilling unportioned food we recommend the use of the appropriate gastronorm tray or similar Likewise placing lids or covers on food will also increas...

Page 7: ...ility and ensures food stays in prime condition whether it is delicate pastries or fish or heavier items such as lasagne and meat casseroles Exceptions depending on the density types and sizes of the...

Page 8: ...of blast soft blast 4 blocks hard blast 2 blocks or freeze single block Freeze option on Blast Chiller Freezer models only 2 By pressing button select timer for the desired duration either 90 or if b...

Page 9: ...ng which a blast cycle cannot be programmed This short interval is to allow defrost water to drain away from the evaporator At the end of each cycle a defrost will automatically clear any ice from the...

Page 10: ...3 have to be linked THERMOSTATS AND PROBES Thermostats The controller can via the set of thermostat parameters control the refrigeration for soft blast chill hard blast chill and chill store All have...

Page 11: ...rapid fluctuations displayed when a door is opened or when the controller is hunting the instantaneous temperature This is achieved by introducing a thermal mass simulation routine in the software to...

Page 12: ...emove all racking shelving and drawer fittings to aid the process Kitchen fats oil and greases can also cause brown spots or stainng to appear on the stainless steel surface For stainless steel with v...

Page 13: ...vider to carry out a full service Note Non compliance may invalidate your Warranty REMOVING THE UNIT COVER Remove the screws in the top and bottom edge of the unit cover and pull the unit cover away f...

Page 14: ...S ITEM Symbol Value Unit Energy Consumption for Chilling Function E 0 108 kWh kg Chilled Full Load Capacity 20 kg Energy Consumption for Freezing Function E 0 878 kWh kg Frozen Full Load Capacity 5 kg...

Page 15: ...Freeze Cycle YES ITEM Symbol Value Unit Energy Consumption for Chilling Function E 0 078 kWh kg Chilled Full Load Capacity 50 kg Energy Consumption for Freezing Function E 0 6785 kWh kg Frozen Full L...

Page 16: ...ails Williams Refrigeration 9 Bryggen Road North Lynn Industrial Estate King s Lynn Norfolk PE30 2HZ Model s WBC70 Type of Product Blast Chiller Refrigerant Fluid s R452A GWP 2140 Blast Chill Cycle YE...

Page 17: ...same quality and standard as we use to build your appliance and have been rigorously checked tested and inspected to ensure the very best quality and exact fit You can contact us directly for everythi...

Page 18: ...rom Williams Refrigeration and not through a wholesaler or other supplier whose warranty terms may be different The Warranty Policy shall be non transferable Replacement of defective equipment can onl...

Page 19: ...control parameters other than those provided as standard factory settings 10 The customer fails to observe commonly accepted operating practices 11 The customer has not properly cleaned or maintained...

Page 20: ...on Hong Kong Unit C 12 F Roxy Industrial Centre 58 66 Tai Lin Pai Road Kwai Chung New Territories Hong Kong Tel 852 2407 5422 Fax 852 2407 3767 sales williams hongkong com www williams refrigeration c...

Reviews: