13
APPLIANCE ROUTINE MAINTENANCE / CLEANING
SHELF / SUPPORT / RACKING REMOVAL
First remove the shelves, then remove the shelf
supports by grasping firmly in the centre and lifting
slightly. Turn the shelf support towards the interior
of the cabinet by pushing it in the centre as you
twist the support through 90°. The shelf support
will be released. (NB: the supports are designed
to be anti-tilt and you may therefore experience
some resistance at first which will be overcome with
practice). When all shelves have been removed,
remove the racking by lifting up and over the nylon
retaining blocks.
CONDENSER CLEANING
(Only applicable to Air Cooled Units)
Regular maintenance should be carried out on a
regular basis by competent / trained personnel. The
condenser is part of the refrigeration unit and is
located in the unit compartment.
Brush fins vertically with a stiff brush, taking care
not to damage them or to push dirt / dust further in,
and then vacuum away.
To cancel the flashing LED, press and hold
for 3
seconds.
If there are further grease deposits still remaining
on the condenser call your Service Provider to carry
out a full service.
Note: Non-compliance may invalidate your
Warranty.
REMOVING THE UNIT COVER
Remove the screws in the top and bottom edge of
the unit cover and pull the unit cover away from the
unit and retaining clips.
CLEANING / REPLACING THE GASKET
Door gaskets should be checked and cleaned
regularly and replaced if damaged. To clean the
gasket, wipe with warm soapy water and a soft cloth,
ensuring it is completely dry before closing the door.
DO NOT
use a sharp knife to clean or scrape the
gasket. Damaged gaskets do not seal correctly and
can increase the amount of electricity consumed,
seriously affecting the efficiency and performance of
the appliance.
Damaged gaskets are easily
replaced. Simply pull out the
existing part and push the new
gasket into the channel (gasket
retainer) at the centre and
work along, pushing gasket into
channel.
EVAPORATOR/DRAINLINE
Inspect periodically to ensure the drain hole is not
blocked.
BREAKDOWN
In the event of a breakdown, please contact Williams
Refrigeration or your Service Provider
When calling, please advise model and serial
number. This information can be found on the data
plate inside the appliance. It should also be noted
on the cover of this Manual. Please ensure that all
redundant parts are disposed of safely and legally.
FIG 2.