background image

Error Codes

7

Wile 200 is equipped with error messages to guide the user to get the 
most reliable results, as well as to ensure that the meter is in good 
condition.

Error code

Cause

Solution

Critical Error 

The meter must be submitted to an 

authorized service center

7

Weight not detected

Repeat test / Do weight test

8

Taring result is too high

Do weight test and check the scale

9

Weight measurement uncertain / 

meter shook during the measure-

ment

Keep the meter stable, 
measurement uncertainty has in-

creased 

10

Moisture measurement result 

stabilize slowly

Happens to very wet samples

11

Weight measurement too un-

certain / meter shook during the 

measurement

Keep the meter stable, measurement 

uncertainty has increased

12

Temperature of the sample lower 

than 2 C / Measurement uncer-

tainty is high

The tester is most accurate when grain 

and tester temperature is between 16C 

and 32C

13

Temperature of the sample above 

50 C / Measurement uncertainty 

is high

The tester is most accurate when grain 

and tester temperature is between 16C 

and 32C

14

Large temp. diff. between the grain 

and test cell / Measurement uncer-

tainty has increased

For better accuracy, grain and meter 

test cell should be at similar tempera-

tures

15

Not on a suffciently level surface, 

meter warns with sound alarm

Keep meter stable during measure-

ment

16

Weight result is over 330 g

Check that leveling handle did not stay 

above the test cell/ Do weight test

17

Weigh result is under 50 g

Check that leveling handle did not stay 

above the test cell/ Do weight test

18

Hectoliter weight is 20% higher 

than average 

Measurement uncertainty has in-

creased, Do weight test

19

Hectoliter weight is 20% lower 

than average  

Measurement uncertainty has in-

creased, Do weight test 

20

Test cell is not cleared before the 

measurement

Clear test cell

Summary of Contents for 200

Page 1: ...Moisture meter EN Operators manual ...

Page 2: ...ees accurate results The meter is equipped with a patented integrated grain leveling system Excess grain goes into the compartment around test cell keeping working area neat during whole measuring process Read this manual carefully to learn how to operate this unit correctly 1 METER 2 CARRYING CASE 3 USB CABLE 4 BATTERIES 5 MANUAL Box Contents 2 1 4 5 3 Kosteusmittari Fukthaltsmätare FI Käyttöohje...

Page 3: ...teries 4 0 Moisture is below the lower limit for this grain 28 0 Moisture is above the upper limit for this grain Error code MEASURING PROCESS Wile 200 guides user step by step directly on the screen during the whole measuring process 1 Place hopper on tester Press and release ON OFF button to turn on tester After power up the display shows the results of the last grain tested 2 Select grain using...

Page 4: ...towards the back of the unit and back removing excess grain 6 When the handle is back to starting position the meter will automatically start measuring Results will appear on the screen within seconds FUNCTIONS AND SETTINGS Settings and functions can be browsed and modified at the settings menu GRAIN OFFSET Each grain can be individually adjusted by 10 0 in increments of 0 1 to match the results o...

Page 5: ... AUTO OFF The meter will turn off automatically after a selected time 30s 1min 5min 10min 20min AVERAGE CALCULATION The meter automatically calculates the average of the previous measure ments In settings menu you can adjust the number of results 3 6 or 9 measurements for the average calculation The average can also be reset BACKLIGHT ON OFF To extend battery life you can turn display backlight of...

Page 6: ...e it on the startup screen automatically but measuring is still possible Low battery voltage does not affect the measurement results WEIGHT TEST Scale function can be checked at weight test mode Use known weight sample up to 500 grams of weight Follow instruction on the screen of your meter INFO Info section shows software version details ...

Page 7: ...st cell MAINTENANCE Use a soft clean cloth to clean device Do not use strong detergents and do not allow liquids inside the meter Keep the meter in a dry place preferably at room temperature If the meter is not used for a long time remove the batteries BATTERY REPLACEMENT The meter uses four AA LR6 batteries Replace all batteries at the same time Temperature sensor ...

Page 8: ... tester is most accurate when grain and tester temperature is between 16C and 32C 13 Temperature of the sample above 50 C Measurement uncertainty is high The tester is most accurate when grain and tester temperature is between 16C and 32C 14 Large temp diff between the grain and test cell Measurement uncer tainty has increased For better accuracy grain and meter test cell should be at similar temp...

Page 9: ... Partner will repair or replace the defected product and return it as soon as possible The warranty does not cover any damages that are caused by incorrect or careless use of the product installation that does not correspond to the provided instructions and other damages which may arise due to causes beyond the control of the manufacturer The liability of Farmcomp Oy is limited to the price of the...