background image

WSG18SFP Switch User Manual

WSG18SFP Switch User Manual

Page 24 of 27

Ping

This command sends ICMP echo request packets to another node on the network.

Ping Parameters

Target IP Address: IP address of the host

Count: Number of packets to send. Select between 1, 5, 10, 20. Default: 1

Time Out: setting the time period of host is Ping. Select between 1,5, 10, 20. Default: 1

Use the ping command to see if another site on the network can be reached. The following are some results of 

the ping command:

Normal response: The normal response occurs in one to ten seconds, depending on network traffic.

Destination does not respond: If the host does not respond, a “timeout” appears in ten seconds.

Destination unreachable: The gateway for this destination indicates that the destination is unreachable.

Network or host unreachable: The gateway found no corresponding entry in the route table.

Press <

> to stop pinging.

Esc

Summary of Contents for WSG18SF

Page 1: ...dware Installation Software Description Login Configuration Administrator Ports Configuration VLAN Setting Trunking Link Aggregation LACP Raid Spanning Tree 802 1X IGMP Snooping Port Mirroring QoS Setting Filter Configuration Rate Limit Configuration Storm Control Monitoring Statistic Overview Detailed Statics LACP Status RSTP Status IGMP Status VeriPHY Ping This manual explains how to log in and ...

Page 2: ...workgroups It can be installed where the space is limited moreover it provides smooth network migration the network capacity can be upgraded easily In addition the switch has comprehensive features such as QoS Quality of Service Spanning Tree VLAN Port Trunking Bandwidth Control Port Security SNMP IGMP Snooping capability via the intelligent software It is suitable for both metro LAN and office ap...

Page 3: ...col IEEE 802 1w Rapid Spanning tree protocol IEEE 802 1p Class of service Priority Protocols Number of Port 16 x 10 100 1000BaseT X UTP SFP combo ports 2 Gigabit SFP Open Slots Mechanical LED Indicator Per Port LINK ACT UTP Port 1 16 1000M SFP Port 1 16 ACT Per Unit Power Power Input 100 240V AC 50 60HZ Product Dimensions Weight 44 220 440 mm H D x W 3kg Performance MAC Address 8K Buffer Memory 50...

Page 4: ...s of 16 x 10 100 1000BaseT X UTP SFP combo ports 2 Gigabit SFP open slots The LED Indicators are also located on the front panel LED Indicators The LED Indicators present real time information of the operation status Table 1 1 LED Indicators LED Status Description Power On Power on Off Power off UTP 1 16 1000M On Port is linked to 1000M Off Port isn t linked to 1000M Link ACT On Link Flashing Data...

Page 5: ...y The flat space should be clean smooth level and sturdy Make sure there is enough of space to attach the cables power cord and allow air circulation Use twisted pair cable to connect this switch to your PC Software Description Open the web browser and type in the URL 192 168 2 1 You see the login screen The factory default did not set up a password so you can just click the button The login proce...

Page 6: ...WSG18SFP Switch User Manual WSG18SFP Switch User Manual Page 6 of 27 Configuration Administrator ...

Page 7: ... are members of VLAN 1 However if the management VLAN is changed the management station should be attached to a port belonging to this VLAN Name type in a new user name default value is admin Password type in a new password default value is admin NMP Enabled enables or disables SNMP on the switch Supports SNMP version 1and 2c management clients SNMP Trap Destination IP address of the trap manager ...

Page 8: ...the length of the cable used to connect to other devices Only sufficient power is used to maintain connection requirements Mode allow user to manually set the port speed as Auto 10 half 10 Full 100 Half 100 Full 1000 Full or Disabled Press button to complete the configuration procedure Apply VLAN Setting A Virtual LAN VLAN is a logical network grouping that limits the broadcast domain which allows...

Page 9: ...orts Load balancing is maintained whenever a link in a trunk is lost or returned to service Aggregation Trunking Configuration To assign a port to a trunk click on the required trunk number then click Apply Link Aggregation LACP IEEE 802 3ad Link Aggregation Control Protocol LACP increases bandwidth by automatically aggregating several physical links together as a logical trunk and providing load ...

Page 10: ...nd reliability RSTP System Configuration System Priority This parameter configures the spanning tree priority globally for this switch The device with the highest priority becomes the STP root device If all devices have the same priority the device with the lowest MAC address becomes the root device Number between 0 61440 in increments of 4096 Therefore there are 16 values Hello Time Interval in s...

Page 11: ...show the RSTP protocol to use Normal use RSTP Compatible compatible with STP RSTP Port Configuration Port The port ID It cannot be changed Aggregations mean any configured trunk group Enabled Click on the tick box to enable disable the RSTP protocol for the port Edge Expect the port to be an edge port linking to an end station or a link to another STP device Path Cost This parameter is used by the...

Page 12: ...WSG18SFP Switch User Manual WSG18SFP Switch User Manual Page 12 of 27 802 1X ...

Page 13: ...r authentication messages Range 1 65535 Default 1812 RADIUS Secret Sets the text string used for encryption between the switch and the RADIUS server This key is used to authenticate logon access for the client Do not use blank spaces in the string Max length 48 characters IGMP Snooping IGMP Snooping is the process of listening to IGMP network traffic IGMP Snooping allows a layer 2 switch to listen...

Page 14: ...lticast traffic Port Mirroring Port Mirroring is used on a network to send a copy of network packets seen on one switch port or an entire VLAN to a network monitoring connection on another switch port This is commonly used for network appliances that require monitoring of network traffic such as an intrusion detection system Mirroring Configuration Port to Mirror to The port that duplicates or mir...

Page 15: ...WSG18SFP Switch User Manual WSG18SFP Switch User Manual Page 15 of 27 ...

Page 16: ...ts are prioritized using the 802 1p field in the VLAN tag This field is three bits long representing the values 0 7 When the QoS Mode is set to 802 1p the 802 1p Configuration table appears allowing you to map each of the eight 802 1p values to a local priority queue low normal medium or high The default settings are shown below When the QoS Mode is set to 802 1p the 802 1p Configuration table is ...

Page 17: ...riority egress queue You can use the Prioritize Traffic drop down list to quickly set the values in the DSCP Configuration table to a common priority queue Use if you want to set each value individually Custom When the QoS Mode is set to DSCP the DSCP Configuration table is displayed as shown below Filter Configuration Administrators can easily assign IP addresses to the ports of the switch Press ...

Page 18: ... Port 1 18 Rate Limit Configuration Select the Port number Policer Set up the ingress bandwidth limit Incoming traffic is discarded if the rate exceeds the value entered Pause frames are also generated if flow control is enabled The format of the packet limits to unicast broadcast and multicast Valid value of Port 1 18 is 128 3968 kbps Default No Limit Shaper Set up the egress bandwidth limit Outg...

Page 19: ...h s performance When the function is enabled and Storm Control rate settings are detected as exceeded the unnecessary frames are dropped There are five types of traffic which can be rate limited including ICMP Rate Learn Frames Rate Broadcast Rate Multicast Rate and Flooded unicast Rate The setting range is 1k 32768k per second Default of four Rates is No Limit ...

Page 20: ...ction s setting press Apply button Monitoring Statistic Overview Statistic Overview for all ports You can mirror traffic from any source port to a target port for real time analysis Detailed Statics Display the detailed counting number of each port s traffic LACP Status LACP Aggregation Overview ...

Page 21: ...t Port number Port Active Shows if the port is a member of an active LACP group Partner Port Number A list of the ports attached to the remote end of this LAG link member Operational Port Key Current operational value of the key used by this LAG LACP Port Status RSTP Status ...

Page 22: ...nds the root device waits before changing state i e discarding to learning to forwarding This delay is required because every device should receive information about topology changes before it starts to forward frames In addition each port needs time to listen to conflicting information that makes it return to a discarding state otherwise temporary data loops can occur Topology Indicates if spanni...

Page 23: ...ompatible mode IGMP Status IGMP Status IGMP Status shows the IGMP Snooping statistics for the whole switch VLAN ID VLAN ID number Querier Shows whether Querying is enabled Queries transmitted Shows the number of transmitted Query packets Queries received Shows the number of received Query packets v1 Reports Shows the number of received v1 Report packets v2 Reports Shows the number of received v2 R...

Page 24: ... 10 20 Default 1 Use the ping command to see if another site on the network can be reached The following are some results of the ping command Normal response The normal response occurs in one to ten seconds depending on network traffic Destination does not respond If the host does not respond a timeout appears in ten seconds Destination unreachable The gateway for this destination indicates that t...

Page 25: ...apply new configuration The procedure of software reset is explained below Reboot Device Warm Restart Press button to restart the switch the reset is complete when the power lights stop blinking Yes Figure 4 1 Load Default Setting Factory Default Factory Default retrieves default settings and replaces the current configuration Except IP address setting all settings are restored to the factory defa...

Page 26: ...n file transfer allows you to save the switch s current configuration or restore a previously saved configuration back to the device Configuration files can be saved to any location on the web management station Select the configuration file to save a configuration or Upload Download to restore a configuration Use the button to choose a file location on the web management Browse station or to find...

Page 27: ...WSG18SFP Switch User Manual WSG18SFP Switch User Manual Page 27 of 27 ...