background image

page 12

Playback: Stills

1.

To view your images, enter MENU and 

press the UP,DN,L or R buttons to navigate 

to the Playback icon and press OK.

2.

Press the UP,DN,L or R button navigate 

through media. To view a image press OK 

on the desired image.

Playback: Videos

1.

To view your videos, enter MENU and 

press the UP,DN,L or R buttons to navigate 

to the Playback icon and press OK.

2.

Press the UP,DN,L or R button navigate 

through media. To view a video press OK 

on the desired video.

ZOOM:

 Press L or R then select the Zoom 

In button. Select       to scroll with the UP, 

DN, L, or R while zoomed in. Select Back 

to return to normal size. Press Back again 

to return to Playback menu.

DELETE:

 Press L or R then select the 

Delete button to delete the selected 

image.

3.

PLAY:

 Press L or R then select the 

Play button. Select Pause to freeze the 

playback. Press Back to return to Playback 

menu.

DELETE:

 Press L or R then select the 

Delete button to delete the selected video. 

NOTE: Once deleted the file cannot be 

recovered.

3.

UP

OK

L

R

DN

BACK

ACTIVE TIME

LOCATION

TRIGGER

DELAY

PIR SENSITIVITY

FLEXTIME 

+

+

DATE & TIME

30

PLAY BACK

IMAGE TYPE

VIEW ASSIST

PLAY BACK

UP

OK

L

R

DN

BA

CK

UP

OK

L

R

DN

BACK

ZOOM

IN

DELETE

ZOOM

OU T

UP

OK

L

R

DN

BACK

ACTIVE TIME

LOCATION

TRIGGER

DELAY

PIR SENSITIVITY

FLEXTIME 

+

+

DATE & TIME

30

PLAY BACK

IMAGE TYPE

VIEW ASSIST

PLAY BACK

UP

OK

L

R

DN

BA

CK

UP

OK

L

R

DN

DELETE

BACK

Summary of Contents for C8B5-7

Page 1: ...Invisible Infrared Digital Cellular Scouting Camera User s Manual Model C8B5 7...

Page 2: ...ludes USB Cable 2 Bungee Cords User Manual Flextime Player Software Camera Unit Antenna NOTE Flextime Player Software is optional Flextime files can be played by using most media players page 1 SIM ca...

Page 3: ...quired Alkaline recommended External power port Capacitor to retain Time and Settings Weather resistant with rubber gaskets 2 Bungee cords included 2G GSM and 3G WCDMA CDMA and CDMA2000 not supported...

Page 4: ...e camera towards you load 2 D batteries with the positive ends towards you in each chamber NOTE Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechargable ni cad ni mh et...

Page 5: ...ot included into the SD card slot with the connectors facing down 7 Load Mini SIM 2FF card into the SIM card slot with the connectors facing down IMPORTANT Make sure the camera is powered off before r...

Page 6: ...are locked during this period UP OK L R DN Test Mode 1 LCD Ready Mode The camera will automatically enter Ready Mode if a button is not pressed for greater than 30 seconds The status lights will illu...

Page 7: ...o navigate to the DATE TIME icon and press OK 2 Press the UP or DN navigation button to go up or down in sequence Press L or R to move to the next digit 3 When the Time Date are set press OK to save a...

Page 8: ...e location of the area the camera was installed This is for your reference and is optional If you do not wish to name your location skip to the next step When the Image Type is set press OK to save an...

Page 9: ...se Takes time lapse images at set intervals during the key movement periods of the day depending on your Flextime settings BOTH Both PIR and Flextime are active When the Image Type is set press OK to...

Page 10: ...to go back to the MENU PIR SENSE HI The PIR detects the smallest movement MED Default The PIR detects most common size movements LOW The PIR detects only larger movements PIR ACTIVE 24 HR The PIR can...

Page 11: ...s INACTIVE INACTIVE INACTIVE INACTIVE INACTIVE PIR PIR FLEXTIME PIR PIR P1 FLEXTIME selected BOTH selected P2 INTERVAL Flextime PIR period 1 15 min before Sunrise to 1 hour after Sunrise 2 1 hour befo...

Page 12: ...back to the MENU Press the L R button to select the mode and press OK to save Then press OK again to go back to the Flextime Display Options See chart on pg 10 for mode descriptions NOTE Cameraneedsa...

Page 13: ...Back to return to normal size Press Back again to return to Playback menu DELETE Press L or R then select the Delete button to delete the selected image 3 PLAY Press L or R then select the Play button...

Page 14: ...and press OK Then press OK again to go to the MMS Settings Press OK to enter up to 3 cell numbers Press the UP or DN navigation button to go up or down in sequence Press L or R to move to the next di...

Page 15: ...on button to go up or down in sequence Press L or R to move to the next digit Press OK when finished Press SAVE to save the email then Press BACK when finished Press CLEAR to clear the email Continue...

Page 16: ...ff if transmitting and or writing an image to memory Make sure there is cellular signal where the camera is being setup Make sure the SIM card is activated before use Cellular settings only work on GS...

Page 17: ...he tree Image Stamp Power Port 1 WGI Cameras come standard with an external power port You must open the weather resistant cover and use a Wildgame Innovations 6 Volt camera battery accessory page 16...

Page 18: ...e cords through the mounting holes on the left or right side of the camera Then stretch the cords around the tree and latch the other ends of the bungee cords through the mounting holes on the opposit...

Page 19: ...e below listed steps are to serve as a guideline and may have to be slightly modified based on the specific operating system and preference as on your personal computer TIPS Recommended distance from...

Page 20: ...will then be illustrated on the right hand side of the window where the Devices with Removable Storage will be listed The computer will recognize the camera as Removable Disk Please select Removable...

Page 21: ...e Disk the SD Card then you will need to go to the Start Menu at the bottom left of your screen and select Computer The summary view will then be illustrated on the right hand side of the window where...

Page 22: ...orts If your computer does not have an SD card port built in you can use an external USB card reader that plugs into any USB port on your computer 2 Click the Start or Windows menu and select Computer...

Page 23: ...adio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not...

Page 24: ...tion of the problem on all enclosed correspondence When possible pack product carefully in original carton Customers are responsible for any shipping cost to WGI Innovations WGI Innovations will pay t...

Page 25: ...page 24...

Page 26: ...dard for wireless device employs a unit of measurement known as the Specific Absorption Rate or SAR The SAR limit set by the FCC is 1 6W kg Tests for SAR are conducted using standard operating positio...

Reviews: