WILDEN PUMP & ENGINEERING, LLC
22
WIL-10330-E-04
T o o l s R e q u i r e d :
Pro-Flo X™
•
3/16" Hex Head Wrench
•
1/4" Hex Head Wrench
•
Snap Ring Pliers
•
O-Ring Pick
CAUTION:
Before any maintenance or repair is attempted, the compressed air line
to the pump should be disconnected and all air pressure allowed to bleed from the
pump. Disconnect all intake, discharge, and air lines. Drain the pump by turning it
upside down and allowing any fl uid to fl ow into a suitable container. Be aware of
hazardous effects of contact with your process fl uid.
The Wilden PX15 metal pump utilizes a revolutionary Pro-Flo
®
air distribution
system. Proprietary composite seals reduce the co effi cient of friction and allow
lube-free operation. The Pro-Flo
®
air distribution system is designed to perform in
on/off, non-freezing, non-stalling, tough duty applications.
Step 1
Loosen the air valve bolts utilizing a
3/8" hex head wrench.
Step 2
Remove muffl er plate and air valve
bolts from air valve assembly
exposing muffl
er gasket for
inspection. Replace if necessary.
Step 3
Lift away air valve assembly
and remove air valve gasket for
inspection. Replace if necessary.
A I R V A L V E / C E N T E R S E C T I O N D I S A S S E M B L Y