Order data

All dimensions in mm

Ordering examples:

50 FR92K fire dampers, DN315 

50 pcs FR92K-31

15 duct frames RB DN160, length 50 mm 

15 pcs FR92K-RB-16-5 

15 protective grilles SG1 with wide edge DN160 

15 pcs FR92K-S1-16

20 connecting piece AR  with non-return valves DN200, length 75 mm 

20 pcs FR92K-AR-20-7

..........  pcs 

fire damper FR92K

 

 

 

 

 

FR92K  -    

 

DN size 

100  125  160  200  250  315

 

 

10 

12 

16 

20 

25 

31

..........  pcs 

limit switch ES

 

 

 

 

 

 

FR92K  -  ES

..........  pcs 

connecting piece AS

 without non-return valve 

FR92K  -  AS  -    - 

 

DN size  

100  125  160  200

    

10 

12 

16 

20

 

  55 

-

  75 

7

 100 

10 

10 

10 

10

..........  pcs 

connecting piece AR

 with non-return valve   

FR92K  -  AR  -    - 

 

DN size   

160  200

    

16 

20

 

 

55 

-

 

 

75 

7

 

 

..........  pcs 

protective grille SG1 with wide edge

  

 

FR92K  -  S1  - 

 

DN size 

100  125  160  200

 

 

10 

12 

16 

20

..........  pcs 

protective grille SG2 with narrow edge

 

 

FR92K  -  S2  - 

 

DN size 

100  125  160  200

 

 

10 

12 

16 

20

..........  pcs 

duct frame RB 

1)

    

 

 

 

 

FR92K  -  RB  -    - 

 

DN size 

100  125  160  200

  

10 

12 

16 

20

  50 

5

 100 

10 

10 

10 

10

1)

 Can only be used with protective grille SG1.

Length 

L

 

[mm]

Length 

L

 

[mm]

Length 

L

 

[mm]

Summary of Contents for FR90

Page 1: ...d walls Sizes DN 100 mm to DN 315 mm Fire classification EI 30 60 90 120 ve ho i o S Options Protective grille DN 100 to DN 200 for air transfer applications Non return valves DN 160 and DN 200 Limit...

Page 2: ...esistant damper blade with elastomer lip seal Leak tightness class 3 according to EN 1751 Large free cross section enables Maximum volume flows Minimum pressure loss Minimum sound levels Release eleme...

Page 3: ...DN 100 to DN 200 see pages 2 and 8 to 10 Connecting piece AR with non return valve and trav erse for screw fastening the protective grille SG1 or SG2 on the non operation side L2 Sizes DN 160 to DN 2...

Page 4: ...ers series FR92K can be used at a velocity of up to 15 m s in the inflow cross section AA and up to 2500 Pa operating pressure FR90 fire dampers in short lengths Dimensioning 1 pressure drop sound pow...

Page 5: ...User Manual 5 12 2019 09 5 Subject to change Series FR92K FR90 fire dampers in short lengths Dimensioning 2 pressure drop sound power level with protective grilles connection Installation on one side...

Page 6: ...metal stud walls each with the appropriate fire resistance period The circumferential gap s and the installation gaps between fire dampers must be 15 mm wide The fillings or mortaring must be made as...

Page 7: ...fire walls shaft walls shafts or ducts Required minimum thicknesses for installation of the fire damper W D mm Fire resistance period in minutes 30 60 90 120 Rigid walls 100 Rigid ceilings 100 The met...

Page 8: ...rten on site to 60 mm 235 75 Shorten on site to 60 mm 75 100 L2 L1 Installation opening DN 50 W D1 SG1 SG1 AS AS The damper blade can be installed with the axis in the vertical or horizontal position...

Page 9: ...non return valve must be installed with vertical axes All longitudinal pipe cuts are then horizontal A maximum deviation of 5 is permissible Install connecting piece AR with the non return valve on no...

Page 10: ...flow Sizes DN 100 DN 125 DN 160 DN 200 D1 mm 125 145 185 235 Connecting pieces AS made of galvanized sheet steel are for fitting onto the fire damper plug connections fitted with lip seals Traverses a...

Page 11: ...ate from combustible materials Are suitable for all installation positions Can be installed with a minimum distance of 15 mm also in metal stud walls Electric wiring must be performed on site Maintena...

Page 12: ...00 125 160 200 250 315 10 12 16 20 25 31 pcs limit switch ES FR92K ES pcs connecting piece AS without non return valve FR92K AS DN size 100 125 160 200 10 12 16 20 55 5 5 5 75 7 7 7 7 100 10 10 10 10...

Page 13: ...anized sheet steel on one side on both sides and with a traverse for screw fastening a protective grille With connecting piece made of galvanized sheet steel on one side with metal non return valve an...

Page 14: ...WEENER EMS Utrecht K LN Factory Administration Telephone 49 0 4951 950 0 Fax 49 0 4951 950 27120 E mail info wildeboer de Internet www wildeboer eu Utrecht office Telephone 31 30 767 0150 E mail info...

Reviews: