Installation
In general
Congratulations on your new WIKING woodburning stove. We are pleased that you have cho-
sen a WIKING woodburning stove and confident that it will give you much pleasure. To ensure
optimum operation and safety, we recommend that the installation should be carried out by an
authorised WIKING retailer or a fitter recommended by the retailer. For an overview of WIKING
retailers, visit www.wiking.com under “Retailer locations”.
Safety
The installation of your WIKING woodburning stove must always comply with all European,
national and local building regulations. The installation must be carried out in accordance with
the instructions in the installation and user manuals and subsequently registered with the local
authorities. Upon installation, the chimney sweep must approve the installation before you can
start using the woodburning stove. All WIKING woodburning stove packaging material must be
handled in accordance with local waste management regulations.
Room requirements
Always ensure a supply of fresh combustion air to the room where the stove is to be installed.
The woodburning stove uses approx.
9-20 m
3
of air per hour. A window that can be opened
or an adjustable air valve will be sufficient. It must not be possible to block the adjustable air
valve/grate. In newly built/airtight dwellings, we recommend that a fresh air system should be
installed for the direct supply of external air to the combustion. This fresh-air system may be
bought separately.
Before installing the stove, you must ensure that the load-bearing capacity of the floor can
withstand the weight of the stove and the chimney. The weight of the chimney should be cal-
culated according to its dimensions and height.
Technical measures and data
Test results from nominal test EN 13240
Nominal heating effect
7.0 kW
Flue gas temperature EN 13240 measurement point
286ºC
Flue gas temperature measured in the outlet socket
343ºC
Exhaust gas flow
5.2 g/s
Efficiency
81 %
Annual efficiency (EcoDesign)
71 %
PM
5 mg/m
3
OGC
67 mg/m
3
NO
2
101 mg/m
3
CO at 13% O
2
1187 mg/m
3
CO at 13% O
2
0.0949 %
Energy efficiency index
107
Energy efficiency class
A+
Test result based on NS 3058
Particle emissions
2.46 g/kg
The declaration of performance (DoP) can be downloaded from our website, www.wiking.com.