WIKA operating instructions model TFS35
11610115.04 11/2019 EN/DE/FR/ES
15
EN
8. Specifications
Specifications
Temperature ranges
Reset Switching Temperature
(RST)
Typically 15 ... 40 K below the switching temperature
To ensure a safe reset of the switch at low switching
temperatures, care must be taken that the temperature
difference between the measuring point and environment
is high enough; since otherwise the switch cannot cool
back down to the reset switching temperature and thus the
instrument will not be able to return to its normal state.
Ambient temperature
Note:
Due to short installation length there is a risk that
the temperature at the connector will rise up to an
inadmissibly high value. This absolutely must be taken
into account when designing the measuring point. The
temperature at the connector must not exceed the above
mentioned temperature range.
- Rectangular connector per
EN 175301-803
-40 ... +100 °C
- AMP Junior Power Timer
connector
-40 ... +130 °C
- Circular connector M12 x 1
-40 ... +90 °C
Static operating pressure
Max. 50 bar
Max. switching voltage
Resistive load (cos ϕ = 1):
■
AC 48 V, 50/60 Hz, 3 A
■
DC 24 V, 3 A
■
DC 12 V, 4 A
Electrical connection
■
Rectangular connector per EN 175301-803, form A
■
AMP Junior Power Timer connector
■
Circular connector M12 x 1
Ingress protection
1)
The ingress protection depends on the electrical connection.
■
Rectangular connector per EN 175301-803: IP65
■
AMP Junior Power Timer connector:
IP66, IP67
■
Circular connector M12 x 1:
IP66, IP67
1) The stated ingress protection only applies when plugged in using mating connectors that have the appropriate ingress
protection.
For further specifications see WIKA data sheet TV 35.01 and the order documentation.
8. Specifications
Summary of Contents for TFS35
Page 16: ...11610115 04 11 2019 EN DE FR ES 16 WIKA operating instructions model TFS35 EN...
Page 30: ...11610115 04 11 2019 EN DE FR ES 30 WIKA Betriebsanleitung Typ TFS35 DE...
Page 44: ...11610115 04 11 2019 EN DE FR ES 44 WIKA mode d emploi type TFS35 FR...
Page 58: ...11610115 04 11 2019 EN DE FR ES 58 WIKA operating instructions model TFS35...