Fine-stranded leads must be finished with end splices.
■
Cables used must comply with the respective requirements in terms of stability and
temperature.
■
Connection cables must be run so that any mechanical damage is prevented.
■
Only connect circuits with the same voltage and type of protection to the switch
contacts and connecting cables.
■
Size the connecting cables for the largest current strength in the circuits.
■
Only connect the TFS35 with extra-low voltage circuits, or with safety extra-low
voltage circuits (SELV) or protected extra-low voltage circuits (PELV).
■
Do not connect circuits simultaneously with low-voltage circuits.
Pin assignment
Circular connector M12 x 1
AMP Junior Power Timer connector
Rectangular connector per DIN EN 175301-803
5. Commissioning, operation