14399527.01 05/2021 EN/DE/FR/ES
12
WIKA operating instructions flow switch, model FSD-4
EN
Risers and vertical pipes
Mounting the flow switch in downpipes open towards the bottom is impermissible. This use does not comply with the
intended use.
5.1.3 Sensor alignment
During mechanical assembly of the FSD-4, make sure
that the installation mark points in the opposite direction
of the flow direction of the medium.
5.1.4 Sealing
For sealing the process connections with parallel
threads, use flat gaskets, lens-type sealing rings or WIKA
profile sealings at the sealing face. With a tapered thread
(e.g. NPT thread), sealing is made in the thread using
additional sealing materials, e.g. PTFE tape (EN 837-2).
For further information on sealings
see WIKA data sheet AC 09.08 or at
www.wika.com
Installation
mark
5. Commissioning, operation
Summary of Contents for FSD-4
Page 68: ...14399527 01 05 2021 EN DE FR ES 68 WIKA operating instructions flow switch model FSD 4...
Page 104: ...14399527 01 05 2021 EN DE FR ES 104 WIKA mode d emploi pour le capteur de d bit type FSD 4 FR...
Page 138: ...14399527 01 05 2021 EN DE FR ES 138 WIKA operating instructions flow switch model FSD 4...
Page 139: ...14399527 01 05 2021 EN DE FR ES 139 WIKA operating instructions flow switch model FSD 4...