28
WIKA operating instructions flow switch, model FSD-3
EN
14153887.01 09/2016 EN/DE/FR
9.
Specifications
Specifications
Measuring ranges
Flow
Water: 5 ... 150 cm/s
Oil: 3 ... 300 cm/s
Temperature (option)
-20 ... +85 °C (-4 ... +185 °F)
Digital display
Type
14-segment LED, red, 4-digit, 9 mm (0.35 inch) character size
Illustration
180° rotatable
Output signals
Switching output
PNP or NPN
Analogue signal (option)
4 ... 20 mA
Pin assignment
see product label
Scaling (temperature)
Zero point: -20 ... +5 °C
End value: 60 ... 85 °C
Switching thresholds
Switch point 1 and switch point 2 are individually adjustable
Switching functions
Normally open, normally closed, window, hysteresis
Freely adjustable
Switching voltage
Power supply - 1 V
Switching current
max. 250 mA
Switch-on drift
10 s
Settling time
Flow (0 ... 100 %, 100 ... 0 %): 6 s
Flow (50 ... 100 %, 100 ... 50 %): 4 s
Temperature t
90
: 4 s
Temperature t
63
: 2 s
Load
Analogue signal 4 ... 20 mA: ≤ 0.5 kΩ
Service life
100 million switching cycles