WIKA operating instructions models DIH50, DIH52
23
EN
14008548.05 12/2016 EN/DE
Model Approvals
Ambient/storage
temperature (in
accordance with the
relevant temperature
classes)
Safety-related
maximum
values for
current loop
(± connections)
Power
supply
U
B
(DC)
DIH50-B
CSA (1946893, LR 66027)
Class I, Division 1 + 2, Groups A, B, C, D
-40 ... +85 °C at T4
-40 ... +75 °C at T5
-40 ... +55 °C at T6
U
i
= 29 V
(V
max
< 29 V)
I
i
= 100 mA
(I
max
< 100 mA)
P
i
= 660 mW
(P
max
< 660 mW)
C
i
= 12 nF
L
i
= 2.2 μH
14.5 ... 29 V
FM (3031500)
Class I, Division 1, Groups A, B, C, D
(IS/I/1/ABCD/T* + IS/I/0AEx ia/IIC/T*)
Class I, Division 2, Groups A, B, C, D
NI/I/2/ABCD/T* + NI/I/2/IIC/T*
DIH50-B
EAC (
ТС RU C-DE.ГБ08.02128
)
0 Ex ia IIC T4/T5/T6
1 Ex ib [ia] IIC T4/T5/T6
DIP A20 Ta 120 °C
DIP A21 Ta 120 °C
-60
1)
/-40 ... +85 °C at T4
-60
1)
/-40 ... +75 °C at T5
-60
1)
/-40 ... +55 °C at T6
U
i
= 29 V
(V
max
< 29 V)
I
i
= 100 mA
(I
max
< 100 mA)
P
i
= 660 mW
(P
max
< 660 mW)
C
i
= 12 nF
L
i
= 2.2 μH
14.5 ... 29 V
DIH5x-F
Flameproof enclosure
BVS 10 ATEX E 158
IECEx BVS 10.0103
-40 ... +85 °C at T4
-40 ... +75 °C at T5
-40 ... +60 °C at T6
U
M
= 30 V
P
M
= 2 W
14.5 ... 30 V
II 2G
Ex db IIC T4/T5/T6 Gb
Ex db IIC T4/T5/T6 Gb
DIH5x-F
Flameproof enclosure
ТС RU C-DE.ГБ08.02128
1 Ex d IIC T6 ... T4
-60
1)
/-40 ... +85 °C at T4
-60
1)
/-40 ... +75 °C at T5
-60
1)
/-40 ... +55 °C at T6
U
M
= 30 V
P
M
= 2 W
14.5 ... 30 V
DIH5x-I
Intrinsically safe equipment
2)
BVS 16 ATEX E 112 X
IECEx BVS 16.0075X
-40 ... +85 °C at T4
-40 ... +75 °C at T5
-40 ... +55 °C at T6
-40 ... +40 °C
(P
i
= 680 mW)
-40 ... +70 °C
(P
i
= 650 mW)
U
i
≤ 29 V
I
i
≤ 100 mA
P
i
≤ 680 mW
C
i
= 13.2 nF
L
i
= 1.2 μH
14.5 ... 29 V
II 2(1)G
II 2(1)D
II 2G
II 2D
IIC T4/T5/T6 Gb
Ex ia [ia Da] IIIC T135 °C Db
Ex ia IIC T4/T5/T6 Gb
Ex ia IIIC T135 °C Db
DIH5x-I
Intrinsically safe equipment
2)
ТС RU C-DE.ГБ08.02128
0 Ex ia IIC T4/T5/T6
1 Ex ib [ia ] IIC T4/T5/T6
DIP A20 Ta 120 °C
DIP A21 Ta 120 °C
-60
1)
/-40 ... +85 °C at T4
-60
1)
/-40 ... +75 °C at T5
-60
1)
/-40 ... +55 °C at T6
-60
1)
/-40 ... +40 °C
(P
i
= 680 mW)
-60
1)
/-40 ... +70 °C
(P
i
= 650 mW)
U
i
≤ 29 V
I
i
≤ 100 mA
P
i
≤ 680 mW
C
i
= 13.2 nF
L
i
= 1.2 μH
14.5 ... 29 V
1) Special version on request (only available with selected approvals)
2) The installation conditions for the display must be considered for the final application.
Output circuit DIH50-B, DIH52-B, DIH50-I, DIH52-I:
U
o
= DC 29.8 V
I
o
= 109.2 mA
9. Information on mounting and operation in hazardous areas