Installation and user manual
UNICOM 300 N531
DDN5006GHEN/04-2021/rev.B1
32
Appendix 1: Schematic display of the functionalities
C.93.40
C.93.41
Inputs
Ingang 2
INP1DIV
1:0.7.1
Enco der
Uit
INP2DIV
2:0.7.2
Vm1
1:23.0.0
Vm2
2:23.0.0
Vm3
3:23.0.0
Ingang 1
Encoder
Pu ls
Alarm contact
Uit
Alarm contact
Encoder Decoder
Gasmeter
7-1:0.2.14
C.91.10
C.91.11
Sw4
Sw6
Micro
INP1
INP3
INP2
Encoder init
Sw4
Stock lock
deactivated
Statusbit:
alarm contact1
Value check
Encoder Read
Statusbit:
alarm contact1
Rx
Tx
UNIGAS 300
Serial Tx Serial Rx
IO Baudra te
IO SW3
IO Ext. Power
IO CONNECT
Schematic display of the functionalities of UNICOM 300 datalogger