2.3 Connecting to the electric network
Check if the voltage stated on the device label complies with rated voltage of alternate voltage
of your electric network.
The device can be connected to electric socket equipped with protective contact installed by
authorized electrician (TN system according IEC 60364). Current circuit of socket must be
protected with 16Amp melting safety fuse or circuit breaker.
The device is delivered with plug according to CEE standard. For other connections remove
delivered plug and use certified plug according national standard..
230V Supply
110V Supply
Net
Wire color
Net
Wire color
L
Brown
L1
Brown
N
Blue
L2
Blue
PE
Yellow/Green
PE
Yellow/Green
2.4
MIG/MAG torch
For torch connecting is used EURO Standard torch connector. Please, tighten the connector
well to eliminate the conduction losses. A loose connection can cause damage of the machine
and torch.
Never use damaged torch!
Make sure the contact tip match the manufacturer’s recommendations for type and diameter
of used wire. Connect the welding conduction main connecting plug into the main socket on
the front side. Secure it with the lock nut.
In case Teflon liner is used is it necessary to use contact neck liner out of brass to provide
good current conduction to the fill wire.