IM 240-i
Operation manual
Seite 18
Manual mode
5.3.2.1
Wire speed setup
Set up wire feed speed in m/min by turning the encoder.
5.3.2.2
Welding voltage setup
Set up the welding voltage in Volts by turning the encoder.
5.3.2.3
Arc length correction
There is possible to adjust length of the welding arc. By
turning the encoder in any direction is display switching
from Voltage mode to Arc length correction mode (% LED
Active).
Arc length = 0 –
Arc length = +30 –
Arc length = –30 –
AMP
%
VOLT
%
VOLT