Aquatronic 3 ultra
OPERATING fUNCTIONS
Power on indicator
(fig.24)
When the electricity supply to the shower is
switched on at the isolating switch, the neon
power indicator will light.
Low pressure indicator
(fig.24)
If this indicator lights, this means the water
pressure has fallen below the minimum required
for correct operation of the shower, resulting in
the low pressure cut-out operating. This switches
off power to the heating elements preventing any
undue temperature rises (water will continue to
flow). Power will automatically be restored when
adequate water pressure returns.
Temperature limiter
During normal operation if an overheat
temperature is sensed power to the elements
will be reduced, although water will continue
to flow. When the temperature has cooled
sufficiently, power to the elements will be
automatically restored to the settings at the time
of interruption.
Safety cut-out
The unit is fitted with a non-resettable thermal
cut-out safety device. In the event of abnormal
operation which could cause unsafe temperatures
within the unit, the device will disconnect the
heating elements. It will require a visit from a
qualified engineer to determine the nature of the
fault and replace the safety device, once the unit
has been repaired.
Power on
indicator
Low pressure
indicator
Fig.
WarnInG!
Do not use ‘powerful’ abrasive or
solvent cleaning fluids when cleaning
the shower as they may damage the
plastic fittings.