background image

CONNECTING THE POWER SUPPLY UNIT (PSU)

Calculate the total current consumption of the Launch Amplifiers, LNB and 

any Series 5WB Multiswitches that make up the complete IRS System. The 

current consumption of the Series 5WB Launch Amplifier range can be found 

in the Specification section of this manual. 

If in doubt, assume the current consumption of each LNB to be 200mA max 

(0.2A). Connect a suitable Whyte PSU to the Auxiliary 18V DC Input. If more 

than  one  PSU is  required,  the  additional  PSU(s) may be connected to any 

other Multi switch, Launch Amplifier, Tap or Splitter within the system. 

When all connections have been made, connect the PSU to a 240V socket to 

power up the IRS System. 

It is highly advisable to isolate and hence divide the system in to DC Groups 

containing  only  a single  PSU  per  group,  by  using  F-type  DC blockers  (not 

supplied).

8

Summary of Contents for WS52-05WB

Page 1: ...NSTRUCTION MANUAL WT51 10WB WT51 20WB WT52 10WB WT52 20WB WS52 05WB www whytetechnologies com In the interest of continuous improvement all specifications of products within this brochure are subject...

Page 2: ...CONTENTS Safety Precautions Guarantee General Description Technical Description Installation Instructions Example Configuration Specifications 3 3 3 4 5 6 9 11 2...

Page 3: ...0 type coaxial cable with a centre core diameter of 1mm When using larger CT125 or CT167 cables you must ensure that suitable F connectors with reducing pins are used otherwise damage to the unit will...

Page 4: ...all Series 5 WB and Series 5 IRS distribution equipment An LED indicates the presence of power in any of the SAT Trunk Lines or at the DC Input TECHNICAL DESCRIPTION Whyte Series 5 WB Taps and Splitt...

Page 5: ...EXAMPLE 5 WIRE 4 WAY SPLITTER EXAMPLE 5 WIRE 5 WAY SPLITTER WT52 10WB WS52 05WB WT52 10WB WT52 10WB 2x Outputs 7dB Loss 1x Outputs 6dB Loss 2x Outputs 10dB Loss 2x Outputs 13dB Loss QUICK FIT COUPLER...

Page 6: ...nnected correctly in the corresponding order with respect to the LNB and the Launch Amplifier SAT inputs Ensure that the F Connectors are properly sealed against water ingress If a Composite Cable mul...

Page 7: ...ding Wire To achieve this strip away 3cm of the insulation of a length of 4mm Earth Bonding Wire See Figure 1 Unscrew the Earth Bolt on the Earth Terminal Bar to provide enough clearance to wrap the E...

Page 8: ...he current consumption of each LNB to be 200mA max 0 2A Connect a suitable Whyte PSU to the Auxiliary 18V DC Input If more than one PSU is required the additional PSU s may be connected to any other M...

Page 9: ...PSU 2 5A DC Block Quick Fit Couplers WM516 WM516 WM516 WM512 WPSU 2 5A WATS 530WB WT52 20WB WT52 20WB WT52 10WB WT52 05WB WSCR504 WM508 WM508 WSCR508 WSCR508 WSCR508 WSCR508 WSCR506 WSCR504 WM516 Quat...

Page 10: ...5A WPSU 2 5A Quick Fit Couplers WPSU 2 5A SAT A SAT B WATS 530WB WT52 20WB WT52 20WB WT52 10WB WT52 05WB WSCR504 WSCR504 WSCR508 WSCR508 WSCR508 WSCR506 WSCR506 WSCR506 WSCR506 WSCR506 WSCR506 WSCR50...

Page 11: ...s which reduces installation time The Whyte Series 5 WB Taps and Splitter feature our intelligent trunk equalisation technology Trunk EQ for flat trunk output This industry first enables longer cascad...

Page 12: ...ap attenuation as well as a 2 way Splitter The Series 5 WB Taps and Splitter can be directly connected to Series 5 and Series D dSCR Multiswitches using the supplied push fit connectors which reduces...

Page 13: ...entre Edison Road Enfield EN3 7XF Tel 0330 999 1980 info whytetechnologies com www whytetechnologies com Technical Support North Region Daniel Hawkins MSCTE 07718 654108 dan whytetechnologies com Sout...

Reviews: