CONNECTING THE SUBSCRIBER CABLES

Terminate  the  Subscriber  Cables  with  good  quality  F  Connectors  and 

connect  to  the  Subscriber  Outputs. The  F  Connectors  should  be  fitted  to 

the  coaxial  cable  correctly,  ensuring  that  the  centre  core  protrudes  3mm 

above the F Connector body. See figure 3. Ensure that you do not exceed 

the bending radius of the Coaxial Cable being used. The Subscriber Cables 

may be arranged either side of the Multiswitch before being terminated and 

connected. If required, the Subscriber Cables may be arranged to one side of 

the Multiswitch, with the cables passing under the Multiswitch before being 

terminated and connected to the Subscriber Outputs on the opposite side. 

See figure 4.

Earth Bonding

Earth  bond  the  Multiswitch  to  the  Earth  Bonding  Lug  and/or  the  Earth 

Terminal Bars using minimum 4mm² Earth Bonding Cable. It is best practise to 

earth bond across the Earth Bars of all components within a single IRS System 

using a single unbroken Earth Bonding Wire. To achieve this, strip away 3cm 

of the insulation of a length of 4mm² Earth Bonding Wire. See Figure 1. 

Unscrew the Earth Bolt on the Earth Terminal Bar to provide enough clearance 

to wrap the Earth Bonding Wire around the Earth Bolt. See Figure 2. Tighten 

the Earth Bolt and route the Earth Bonding Wire to all other Earth Terminal 

Bars and terminate as detailed above. Make sure that the Earth Bonding Cable 

is connected directly to the building’s PME.

Figure 1

Figure 2

3mm

Figure 3

Figure 4

ON

OFF

DC

 

12V

4G

5G

Multiswitch WM516

Freq Range TERR

Freq Range SAT

Gain TERR

Gain SAT 

Max Output TERR

Max Output SAT

Current Consumption

47~790 MHz

950~2150 MHz

9dB

10dB

85dB

µV

100dB

µV

210mA Max

Whyte

REC6

REC2

REC4

REC8

REC10

REC12

REC14

REC16

REC5

REC1

REC3

REC7

REC9

REC11

REC13

REC15

+DC

+DC

DC IN 18V

DC OUT 18V

AUXILIARY

8

9

Summary of Contents for WM508

Page 1: ...switch INSTRUCTION MANUAL WM508 WM512 WM516 WM524 WM532 www whytetechnologies com In the interest of continuous improvement all specifications of products within this brochure are subject to change wi...

Page 2: ...alidate the guarantee The female F connectors on this unit were designed for use with 100 type coaxial cable with a centre core diameter of 1mm When using larger CT125 or CT167 cables you must ensure...

Page 3: ...ompliant with the RED Directive Series 5 Multiswitches are line powered but can also be used as Standalone Multiswitches when powered directly via the18V Auxiliary Input Large scale Integrated Recepti...

Page 4: ...9dB for TERR All inputs come fitted with an individual Gain Control 4G 5G Filtering The range comes fitted with high rejection 4G 5G filters that are selectable via a switch The correct filter should...

Page 5: ...ng minimum 4mm Earth Bonding Cable It is best practise to earth bond across the Earth Bars of all components within a single IRS System using a single unbroken Earth Bonding Wire To achieve this strip...

Page 6: ...ification section of this manual If in doubt assume the current consumption of each LNB to be 200mA max 0 2A Connect a suitable Whyte PSU to the Auxiliary 18V DC Input If more than one PSU is required...

Page 7: ...dB 30dB 25dB 75 13 18V 22kHz DiSEqC 18V DC YES YES YES 230mA LED 2A 12V DC 100mA YES Up to 6mm core 342 x 182 x 43mm 1512g WM516 WM524 WM532 SAT TERR SAT TERR SAT TERR SAT Trunk Input Output TERR Trun...

Page 8: ...Unit 13 Watermill Business Centre Edison Road Enfield EN3 7XF Tel 0330 999 1980 info whytetechnologies com www whytetechnologies com Copyright Whyte Technologies June 2020...

Reviews: