background image

Installation

6

7

Control Panel

1.  Set temperature indicator

2.  Room temperature indicator

3.  Low fan speed indicator

4.  High fan speed indicator

5.  Automatic mode indicator

6.  Cooling mode indicator

7.  Fan mode indicator

8.  Heating mode indicator

(for models with heating options)

Mounting the exhaust pipe

•  The supplied exhaust hose can be

extended from 1 foot to 5 feet
for mounting. It is recommended that
you use the shortest possible length of hose.

•  Take care to prevent any kink or

bend in the middle of the exhaust
hose, as this will trap hot exhaust air,
which will radiate back into the room.

Installation of the Carbon Filter

Setting Mode/Function

Press the MODE button to select the required working mode: Automatic, Cooling, Fan or Heating (Heating is only 
available for ARC-12H). The green indicator illustrating your selected mode lights up.  It is recommended to select 
Cooling or Heating mode and set your desired temperature, as the Auto mode has a preset temperature (please 
see below) that cannot be changed.
The indicators of the functions in progress come on at the same time, e.g. Cool and Lo = Cooling mode with Low fan speed.

Auto Mode

When this mode is selected, the unit is preset to the following temperature settings and unit will only start to:
• Cool when room temperature is higher than 75ºF 
• Heat when room temperature is lower than 68ºF (ARC-12H only)
If room temperature is between 68ºF and 75ºF, unit will stay in Fan mode.  Again, when in Auto Mode, the temperature 
settings cannot be changed. 

Setting the Temperature in Cooling or Heating Mode

T

he display window’s default is to display the ambient room temperature.  The green indicator light under RT is on.  

(RT = Room Temperature)
To set your desired temperature, press the Temperature up or down buttons (ranging from 62ºF to 90ºF).  Each 
press will increase or decrease your set temperature by 1ºF.  When pressing the temperature up or down buttons, 
the window will change to display your set temperature. At this time, the green indicator will light under ST (Set 
Temperature).  Once the temperature up or down buttons is released, the window will return to displaying the 
ambient temperature after a second. 
Note:  When unit is in the following modes:   Auto, Cool, or Heat - the compressor will cool/heat the room to 
reach the set temperature.  Once the ambient temperature has reached the set temperature, the compressor will 
stop and unit will run in Fan mode.  To conserve energy, the compressor will not start immediately after a couple 
degrees increase or decrease, but will wait for a 5ºF allowance.  For example:
In Cooling Mode with a set temperature of 70ºF
When compressor first stops after reaching 70ºF, unit will auto-switch to Fan. 
Compressor will start cooling again when ambient temperature increases to 75ºF or above.
In Heating Mode with a set temperature of 72ºF
When compressor first stops after reaching 72ºF, unit will auto-switch to Fan. 
Compressor will start heating again when ambient temperature drops to 67ºF or below.
In Auto Mode (with preset temperature of 68ºF for heat and 75ºF for cool)
Compressor will start cooling again when ambient temperature reaches above 80ºF or will start heating when
ambient temperature drops below 63ºF.

9. Timer operation indicator

10.  Compressor Indicator

11.  Temperature up selector

12.  Temperature down selector

13.  Fan speed selector

14.  Mode (function)

option selector

15.  Timer selector

16.  ON/OFF (power) selector

17.  Display window

1.  Remove the filter frame from the unit by

pressing down on tabs and pulling forward.

2. Separate the filter from the filter frame.
3. Remove the active carbon filter 

from its plastic bag.

4. Insert the active carbon filter 

into the filter frame.

5.  Fix the filter by reassembling 

the fixer onto the filter frame.

6.  Re-fit the filter frame

inside the unit.

7.  It is recommended to

replace the carbon filter
every 3 to 6 months.

WARNING!

The length of the exhaust pipe is specially
designed according to the specification of
this product. 
Do not replace or extend it with your own hose
as this could cause the unit to malfunction.

Operation

2

4

3

5

Summary of Contents for SNO ARC-12D

Page 1: ...he expiration of the warranty the cost of labor and parts will be the responsibility of the original owner of the unit THISWARRANTY DOES NOT COVER Acts of God such as fire flood hurricanes earthquakes...

Page 2: ...the unit in the recommended room size refer to SPECIFICATIONS Do not locate the air conditioner where furniture or other objects can obstruct the airflow Keep blinds curtains closed during the sunnie...

Page 3: ...nnect the unit to the power source Make sure the unit is connected to a correctly grounded power supply refer to the rating label located at the back of the unit An opening in a window or wall is requ...

Page 4: ...ng mode the compressor will switch off if the room temperature is HIGHER than the one set the fan keeps working at the set level When the room temperature drops 5 F below the chosen temperature heatin...

Page 5: ...play your set temperature At this time the green indicator will light under ST Set Temperature Once the temperature up or down buttons is released the window will return to displaying the ambient temp...

Page 6: ...l Water indicator should be off now 7 Replace the drain knob By Water Tube Continuous Drainage 1 Remove the drain knob and rubber plug and keep them for future use 2 Connect a suitable water tube of 3...

Page 7: ...rigerant R 22 R 22 Fan Speed 2 2 Timer 1 12 hours 1 12 hours Thermostat 62 F 90 F 62 F 90 F Net Weight 65 lbs 68 lbs Dimensions 16 W x 17 D x 30 H 16 W x 17 D x 30 H Working Temperature Cooling 62 F t...

Page 8: ...er 6 OPERATION 7 Control Panel 7 Turning On Off 7 Setting Mode Function 7 Auto Mode 7 Setting theTemperature 7 Setting Fan Speed 8 Setting theTimer 8 Regulating Airflow Direction 8 DRAINAGE 9 By Drain...