background image

Installation

5

Operation

8

Setting The Fan Speed

Press the SPEED button to choose the fan speed you require, high or low.  The indicator of high 
or low fan will light up at the same time.
If the unit is in AUTO mode, it will select the fan speed automatically according to the
ambient temperature (the related indicators, cool, fan or heat will light up), at this time the
fan speed switch is invalid.

Setting the Timer

Press the TIMER button to set the operating hours you desire (1 to 12 hours, the timer
indicator will light up).  When the set time has elapsed, the machine will turn off
automatically.  The display window will show the hour(s) you set as you press the TIMER button. 
If the timer button is not pressed, the unit will work continuously.
By pressing the timer button but without turning on the unit, you can PRE-SET the time for
the machine to work.  For example, if you press the timer to ‘2’, the unit will come on
automatically after 2 hours.
All the above functions can also be performed with the supplied remote
control.  This remote control requires 2 AAA batteries to operate.

Regulating the airflow direction

IMPORTANT!

•  The compressor will start approximately 3 minutes after the unit is turned on (this will 

help prolong the life of the compressor).  After switching the unit off, please wait at least
3 minutes before turning the unit back on.

• The cooling system will switch off if the room temperature is lower than set.  The fan, however, keeps 

working at the set level.  If the ambient temperature rises above the chosen tempe/-5

°

F, 

the cooling will resume.

•  In heating mode, the compressor will switch off if the room temperature is HIGHER than the one set 

(the fan keeps working at the set level).  When the room temperature drops 5

°

F below the chosen 

temperature, heating will resume.

•  This machine is equipped with an ANTI-FROST function.  Sometimes, while using the heating function 

during low temperatures, the heating will stop for a while to melt the internal frost.  When this occurs, 
wait for heating to resume.

•  As you switch on the heating, the fan will stop for 15-20 seconds prior to the unit starting.

Wall Connection

1. Make a hole (5.1" in diameter) 

in the wall.

2. Insert the Round Connector 

(part #14) into the hole and 
hold in place by using 4 small 
screws (not supplied).

3. Extend one end of the exhaust 

pipe (part #11) and screw into 
the Round Connector by 
turning clockwise.

4. Extend other end of exhaust 

pipe and screw in Adaptor (part 
#10) by turning clockwise.

5. Push Adaptor to fit firmly 

over the opening on the back 
of the unit.

** When not in use, cover the 

Round Connector and hole 
with Cap (part #15).

2. Attach Slide Bar Connector, 

(Round Connector) to the 

other end of the Hose by 

extending hose at least 6". 

Then tighten Hose by turing 

the (Round Connector) 

clockwise.

Window Kit Installation 

In order for this unit to function 

properly, it must be vented to the 

outside.
Fitting the Exhaust Hose through 

the window is easy. Please see 

below.
1. Extend Hose at least 6" and 

insert it into back of the unit, 

tightening into place by turning 

it clockwise.

3. Place Adjustable Slide Bar in 

the wondow and expand so it 

fits tightly.

4. Lower the windwo.
5. Make sure the Hose has no 

kinks.

Slide Bar has 3 sections which 

allows installation in windows up 

to 48" in width.

Turn the roller on the air vent to control 

the airflow direction from the vertical louvres.

Summary of Contents for SNO ARC-12D

Page 1: ...he expiration of the warranty the cost of labor and parts will be the responsibility of the original owner of the unit THISWARRANTY DOES NOT COVER Acts of God such as fire flood hurricanes earthquakes...

Page 2: ...the unit in the recommended room size refer to SPECIFICATIONS Do not locate the air conditioner where furniture or other objects can obstruct the airflow Keep blinds curtains closed during the sunnie...

Page 3: ...nnect the unit to the power source Make sure the unit is connected to a correctly grounded power supply refer to the rating label located at the back of the unit An opening in a window or wall is requ...

Page 4: ...ng mode the compressor will switch off if the room temperature is HIGHER than the one set the fan keeps working at the set level When the room temperature drops 5 F below the chosen temperature heatin...

Page 5: ...play your set temperature At this time the green indicator will light under ST Set Temperature Once the temperature up or down buttons is released the window will return to displaying the ambient temp...

Page 6: ...l Water indicator should be off now 7 Replace the drain knob By Water Tube Continuous Drainage 1 Remove the drain knob and rubber plug and keep them for future use 2 Connect a suitable water tube of 3...

Page 7: ...rigerant R 22 R 22 Fan Speed 2 2 Timer 1 12 hours 1 12 hours Thermostat 62 F 90 F 62 F 90 F Net Weight 65 lbs 68 lbs Dimensions 16 W x 17 D x 30 H 16 W x 17 D x 30 H Working Temperature Cooling 62 F t...

Page 8: ...er 6 OPERATION 7 Control Panel 7 Turning On Off 7 Setting Mode Function 7 Auto Mode 7 Setting theTemperature 7 Setting Fan Speed 8 Setting theTimer 8 Regulating Airflow Direction 8 DRAINAGE 9 By Drain...

Reviews: