 14 

TURBO FUNCTION

 

Turbo function will be helpful to cool or heat your room quickly and effectively by operating at the maximum fan 
speed. 

NOTE: Turbo function is only available in Cool and Heat  mode. 
 
LOUVER ANGLE MEMORY FUNCTION 

Power failure during operation or pressing the ON/OFF button on the remote control will stop the unit completely. 
When the power restores or pressing the ON/OFF button on the remote control again, the unit restarts automatically 
with the previous open angle of the horizontal louver by the louver angle memory function. Press the AUTO/COOL 
manual button (on the indoor unit) and the open angle of the horizontal louver will be restored to the standard angle.  

NOTE: It is highly recommend that the open angle of the horizontal louver should not be set too small, in 
case the condensed water forms and drops from the horizontal louver.  
 
FOLLOW ME FUNCTION

 

The remote control serves as a remote thermostat allowing for the precise and comfortable temperature control. 
With this technology, an efficient temperature sensor is integrated in the remote control. To activate the Follow me 
function, press Follow Me button on the remote control. Once this function is activated, the remote control will send 
the temperature signal to the air conditioner every 3 minutes interval until you press the Follow Me button again. The 
air conditioner will automatically cancel the Follow Me feature if it does not receive the signal during any 7 minutes 
interval. 

NOTE: The Follow Me feature is not available in DRY and FAN mode. Shifting the operating mode or turning 
off the unit will cancel the Follow Me feature automatically. The remote control needs to be within 26 feet reach of 
the indoor unit for the Follow Me mode to work appropriately. 
 
SELF-CLEAN FUNCTION 

Self Clean function will prevent growth of harmful micro-organisms by eliminating the moisture inside of the indoor 
unit. In this function, the indoor unit will run in fan mode for 11 minutes. Once the time has elapsed, a low heat oper-
ation will run for 1 minute and will then switch to fan mode for another 2 minutes. The appliance will automatically 
shut-off once the cycle completes. 

NOTE: It is recommended the use the Self Clean function every 15 days. In high  humidity environment, use it in 
a weekly basis. This will prevent rusting of the air conditioner’s evaporator coil.
 
 
SILENCE FUNCTION 

Press the “Silence” button on the remote control to initiate Silence function. When the Silence function is activated, 
the compressor will run at a low frequency rate and the indoor unit will bring faint breeze, which will reduce the noise 
to the lowest level and create a quiet and comfortable environment. 
 

LOW TEMPERATURE HEATING (FP mode) 

The FP (Freezing Protection) mode is designed to run at ambient temperature as low as 46°F / 8°C, which keeps the 
room temperature at a comfortable level during the winter season. 

NOTE: This unit uses heat pump for heating and the heating mode does not work when temperature is be-
low 45°F.

 

 

REFRIGERANT LEAKAGE DETECTION

 

With this safety feature, the indoor unit will display “EC” when it detects a refrigerant leakage.   
 

ANTI-COLD AIR FUNCTION 

The unit is designed not to blow cold air on HEAT mode when the indoor heat exchanger is in one of the following 
three situations and the set temperature has not been reached.  
A)  When heating has just started 
B)  Defrosting 
C)  Low temperature heating 
To prevent cold air flow, the indoor unit’s fan will stop if the indoor coil temperature is lower than 62°F(17°C). The fan 
operation will resume once the indoor coil’s temperature is higher than 88F. 

SPECIAL FUNCTION FEATURES 

Summary of Contents for MSFS-009H11517-01NE

Page 1: ...on please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference INSTRUCTION MANUAL MSFS 009H11517 01NE MSFS 012H11517 01NE MSFS 012H115...

Page 2: ...7 PARTS IDENTIFICATION 8 OPERATING TEMPERATURE USING THE REMOTE CONTROL 9 FEATURES OF THE REMOTE CONTROL DISPLAY 10 11 MODES OF OPERATION INSTRUCTIONS 12 13 SPECIAL FUNCTION FEATURES DISPLAY PANEL 14...

Page 3: ...f this product can be obtained from your local municipal au thority Thank you for choosing the Whynter Air Conditioner Inverter Ductless Mini Split System Air Conditioner Heat Pump Please follow the i...

Page 4: ...onnections tightly and waterproof to avoid risk of electrical shocks or fire due to insufficient contact All power wires breakers and other components used to supply power to the unit must be approved...

Page 5: ...nance and repairs easily Suffi cient clearances must be provided at all directions for removal of various panels If you see lightning or hear thunder there might be a lightning strike To prevent elect...

Page 6: ...air condi tioning mini split air conditioner mini ductless ac and others Ductless Mini Split system uses 2 Units One Inside Indoor unit the evaporator and One Outside Outdoor unit the condenser Essen...

Page 7: ...294 CFM 589 CFM 852 CFM Maximum Power Consumption 782W 7 0Amps 1200W 10 4Amps 960W 8 4Amps 1090W 4 8Amps 2525W 11 2Amps 4235W 18 5Amps Power Supply 115 V 60Hz 115 V 60Hz 115 V 60Hz 230 V 60Hz 230 V 6...

Page 8: ...all prevail Wall Mounting Plate Front Panel Louver Indoor Unit Power Cable Drainage Pipe Signal Cable Refrigerant Piping Outdoor Unit Power Cable Remote Control Remote Control Holder Temperature Displ...

Page 9: ...f up to 15 minutes may occur CAUTION To prevent malfunction or damage of the remote control Do not place the remote control at where will not be exposed to direct sunlight or excessive heat Remove bat...

Page 10: ...light display Press this button to initiate the Follow Me fea ture and the remote control will display the tem perature at its location The remote control will send this signal to the air conditioner...

Page 11: ...N func tion 10 TIMER OFF Button Press the Timer Off button to program Timer Delayed Switch OFF func tion 11 DIRECT Button Press to change the louver movement and set the desired up down air flow direc...

Page 12: ...icator display comes on Please note that when switching function mode there will be an approximately 3 minute transition time NOTE Fan speed is defaulted to AUTO and cannot be changed in Dry Mode FAN...

Page 13: ...RECT button to change the louver movement and set the desired up down air flow direction The louver changes 6 in angle for each press NOTES A fixed louver angle in a high horizontal angle is recommend...

Page 14: ...t for the Follow Me mode to work appropriately SELF CLEAN FUNCTION Self Clean function will prevent growth of harmful micro organisms by eliminating the moisture inside of the indoor unit In this func...

Page 15: ...nF as a reminder replace air filters Temperature Display Window MANUAL OPERATION WITHOUT REMOTE CONTROL In the event that your remote control fails to work your unit can be operated manually with the...

Page 16: ...ir intake is filtered properly and to assure that your air condi tioner runs efficiently it is recommended to clean the washable high density filters at least once every two weeks Lift the indoor unit...

Page 17: ...n on your remote control 4 times or press the MANUAL CONTROL button 3 times If you don t reset the reminder the nF indicator will flash again when you restart the unit CAUTION Any maintenance and clea...

Page 18: ...a sudden and large temperature difference between air inlet and air outlet in COOL or DRY mode This is common when the relative humidity is high Mist or steam may be generated due to moisture generat...

Page 19: ...ng opera tion When the outdoor temperature falls heat drawn in by the air conditioner decreases accordingly At the same time heat loading of the air conditioner increases due to larger difference betw...

Page 20: ...units Low hissing sound when the system starts has just stopped running or is defrosting This noise is normal and is caused by the refrigerant gas stopping or changing direction Squeaking sound Normal...

Page 21: ...se Remote control batteries are dead Replace batteries The unit s 3 minute protection has been acti vated Wait three minutes after restarting the unit Timer is activated Turn timer off The unit starts...

Page 22: ...e Should the compressor prove defective in materials or workmanship under normal residential usage at the installer s determination during the two years following the initial one year parts warranty W...

Reviews: