What should I look for first when purchasing a portable air conditioner?

The right air conditioner helps you cool a room efficiently. An undersized unit won't cool adequately while one that's too 

large will not remove enough humidity, leaving the air feeling damp. To find the proper air conditioner, determine the 

square footage of the room you want to cool by multiplying the room length by its width. You also need to know the air 

conditioner's BTU (British Thermal Unit) rating, which indicates the amount of heat it can remove from a room. A higher Why 

is the cooling capacity lower on newer models than on older units? number means more cooling power for a larger room. 

(Be sure you are comparing only newer models to each other- older models may appear to have a higher capacity, but are 

actually the same). Be sure to “size up” if your portable air conditioner will be placed in a very sunny room, in a kitchen, or in 

a room with high ceilings. After you’ve found the right cooling capacity for your room, you can look at other features.

Why is the cooling capacity lower on newer models than on older units?

Federal regulations require manufacturers to calculate cooling capacity based on a specific test procedure, which was 

changed just this year. Models manufactured before 2017 were tested under a different procedure and cooling capacity is 

measured differently than in prior years’models. So, while the BTUs may be lower, the actual cooling capacity of the air 

conditioners has not changed.

What is SACC ?

SACC is the representative value of Seasonally Adjusted Cooling Capacity, in Btu/h, as determined in accordance with the 
DOE test procedure at title 10 Code of Federal Regulations (CFR) 430, subpart B, appendix CC and applicable sampling plans.

TECHNICAL DATA 

Model: 

ARC-147WF

Operational Modes: 

Air conditioner, Fan, or Dehumidifier 

Cooling Capacity (SACC): 

ASHRAE: 14000 BTU / SACC: 10000BTU

Coverage Area: 

400 sq. ft. 

Dehumidifying Capacity: 

134 Pts / day 

Fan Speed: 

3 Fan Speed 

Filters: 

HEPA and activated carbon filter

Thermostat Control Range: 

61° - 90°F 

Timer: 

24 hour programmable timer 

Noise Level: 

<54 dBA 

Extendable Hose: 

Length up to 60" 

Window Kit Length: 

Minimum: 20” 

Maximum: 46” 

Refrigerant: 

R32

Air Flow (at high speed): 

460 m3/h / 270 CFM 

Maximum Power Consumption: 

1341W / 11.8A 

Power Supply: 

115 V / 60Hz 

CEER: 

7.83 

Unit Dimensions: 

17.74" W x 15.81" D x 30.87" H 

Net Weight: 

Gross Weight: 

83.83 lbs 

92.77 lbs 

Hose connectors: 

6" diameter

Summary of Contents for ARC-147WF

Page 1: ...struction Manual carefully before using this product Keep this manual in a safe place for future reference Model ARC 147WF Whynter Portable Air Conditioner with Dual Hose Dehumidifier Fan up to 500 sq ft 14000 BTU 10000 BTU SACC Remote Control HEPA and Carbon Filter White INSTRUCTION MANUAL ...

Page 2: ...Exhaust Hose Installation 7 Choosing The Right Location Ambient Temperature Range For Unit Operation 7 Technical Data 8 Accessories 9 Control Panel 10 11 Remote Control 12 Installation 13 Maintenance 14 15 Troubleshooting 16 17 Table of Contents 7 Warranty 18 ...

Page 3: ...acle Install the unit on a flat sturdy surface Failure to do so could result in damage or excessive noise and vibration The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards Do not modify the length of the power cord or use an extension cord to power the unit Do Do not share a single outlet with other electrical appliances Improper power supply can cau...

Page 4: ...liance must be disconnected from the supply mains Do not remove any fixed covers Never use this appliance if it is not working properly or if it has been dropped or damaged Do not run cord under carpeting Do not cover cord with throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over Do not ope...

Page 5: ...lated area where the room size corresponds to the room area as specified for operation Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry accredited assessment authority which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification Servicing s...

Page 6: ...nation of symbols displayed on the unit WARNING CAUTION CAUTION CAUTION This symbol shows that this appliance used a flammable refrigerant If the refrigerant is leaked and exposed to an external ignition source there is a risk of fire This symbol shows that the operation manual should be read carefully This symbol shows that a service personnel should be handling this equipment with reference to t...

Page 7: ...usage mode For COOL mode the exhaust hose must be installed For FAN or DRY mode the exhaust hose can optionally be removed Choosing The Right Location Your installation location should meet the following requirements Make sure that you install your unit on an even surface to minimize noise and vibration The unit must be installed near a grounded plug and the Lower Drain Port found on the back of t...

Page 8: ...its Federal regulations require manufacturers to calculate cooling capacity based on a specific test procedure which was changed just this year Models manufactured before 2017 were tested under a different procedure and cooling capacity is measured differently than in prior years models So while the BTUs may be lower the actual cooling capacity of the air conditioners has not changed What is SACC ...

Page 9: ...s Note Remove and discard Accessories ACCESSORY IMAGE ACCESSORY DESCRIPTION QUANTITY 1 Exhaust Intake Hose 2 pieces 2 Hose Connector to Unit 2 pieces 3 Hose Connector to Window Kit 2 pieces 6 pieces Covers 2 pieces Window slider kit 1 set Remote control 1 piece 1 3 2 A B C ...

Page 10: ...depending on which auto function is chose To cancel the delayed switch off function turn off the air conditioner or adjust the time setting to 0 0 5FNQFSBUVSF POUSPMT Press to adjust the temperature setting The default display is room temperature In cooling mode when or button is pressed the set temperature is displayed and may be adjusted After a few seconds the display will revert back to room t...

Page 11: ...P UIF PVUTJEF BOE DPPMJOH XJUIJO UIF SPPN NBZ PDDVS G UIF FYIBVTU IPTF JT OPU WFOUFE UIF VOJU NBZ SFRVJSF NPSF GSFRVFOU ESBJOJOH EEJUJPOBMMZ UIF BJS DPOEJUJPOFS EPFT OPU IBWF B IVNJEJTUBU JO XIJDI B TQFDJGJD IVNJEJUZ MFWFM DBO CF TFU BO PEF In this mode only the fan of the air conditioner runs and circulates the air in the room To activate this function mode press the MODE button until the FAN ind...

Page 12: ...ssing the key or LCD Display Fahrenheit Celsius Battery Placement Remove the cover on the back of the remote control and insert the batteries with the and poles pointing in the proper direction CAUTION Use only AAA batteries Remove the batteries if the remote control is not used for a month or longer Do not attempt to recharge the supplied batteries All batteries should be replaced at the same tim...

Page 13: ...and nuts mounted on the two ends of the main panel A 1 Slide each hose assembly with the hose connector to unit into the exhaust and intake ports of the rear panel firmly in place 3 Open the window and place the window panel kit into the window Adjust the extension panels B and C to fit width or height of window using the screw and nut sets mounted on the main panel A Installation ...

Page 14: ...g on use 1 Switch off the air conditioner 2 Pull the pre filter frame from the unit 3 Remove the activated carbon filter from the pre filter 4 Use a vacuum cleaner or tap lightly to remove loose dust and dirt from the pre filter 5 Rinse the pre filter thoroughly under warm running water no hotter than 100 F 6 Dry thoroughly before re inserting the filters NOTE The activated carbon filter and HEPA ...

Page 15: ...Gather the power cord and bundle it Remove the batteries from the remote If leaving the window kit in place disconnect the exhaust and intake hose from the window slider kit and place the included covers on the kit Otherwise remove the window kit from the window opening Note Depending on use it is recommended that the air conditioner be cleaned internally annually Please contact Whynter at support...

Page 16: ...rn on the fan runs but the unit is not cooling The room temperature is outside of the operational tolerances of the unit The Cooling mode is not on The compressor has not turned on yet because of its time delay The set temperature is too high The internal water reservoir is full and the TANK FULL indicator appears on the display This unit is designed to work in ambient temperatures of 63 F to 90 F...

Page 17: ... You may need additional cooling or another air conditioner Close curtains or blinds and try to minimize the amount of direct sunlight into the room You may need additional cooling or another air conditioner The unit is very noisy The unit is not level The surface underneath the unit is uneven Low power voltage Make sure the unit is on hard level and stable surface Move the unit to a location with...

Page 18: ...s Use in commercial or industrial applications Damage accidental or otherwise to the product while in the possession of a consumernot caused by a defect in material or workmanship Damage caused by consumer misuse tampering lack of maintenance or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear D...