INTRODUCTION / TECHNICAL DATA 

HOW IT WORKS

 

The Whynter compact CFC-free, lead-free, and energy efficient 12,000 BTU portable air condition-er, helps you stay 
cool while working with better environmental standards and reducing energy con-sumption. 

This high output portable air conditioner, specially designed to be mobile, can be easily setup in almost any indoor 
location and is most commonly used in data closets / server rooms, bedrooms, classrooms and garages / 
workshops. 

This Whynter ARC-126MD portable air conditioner features an ECO-FRIENDLY CFC-free GREEN R-410A 
refrigerant and lead-free RoHS compliant components.

Operationally, a dual hose portable air conditioner has two main advantages over a single hose unit. A dual hose 
portable air conditioner 

can help

 cool a room faster and will help minimize 

negative air

 

pressure situation in the

room. If the outside temperature is much higher or more humid than the room, the intake hose can be detached and 
the unit will function as a single hose unit.  

TECHNICAL DATA 

Model: 

ARC-126MD

B

Operational Modes: 

Auto, Air conditioner, Fan or Dehumidifier 

Cooling Capacity: 

12000 BTU 

Coverage Area: 

450 sq. ft. 

Dehumidifying Capacity: 

61 Pts / day 

Fan Speed: 

3 Fan Speeds 

Filters: 

Thermostat Control Range: 

62° - 88°F 

Timer: 

24 hour programmable timer 

Noise Level: 

<55 dBA 

Extendable Hose: 

59” 

Window Kit Length: 

Minimum: 26.5” 

Maximum: 48” 

Refrigerant: 

R-410A

Air Flow (at high speed): 

497 m

3

/h / 292 CFM 

Maximum Power Consumption: 

1355W / 11.8A 

Power Supply: 

115 V / 60Hz 

EER: 

8.9 

Unit Dimensions: 

18.5" W x 18.75" D x 30.25" H 

Package Dimensions: 

20.75” W x 20.75" D x 35" H 

Net Weight: 

72.75 lbs 

Gross Weight: 

81.5 lbs 

3M Filter and Silvershield washable pre-filter 

Intake hose pre-filter

Summary of Contents for ARC-126MDB

Page 1: ...ation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference Model ARC 126MDB INSTRUCTION MANUAL WHYNTER 12 000 BTU DUAL HOSE POR...

Page 2: ...ORMATION 3 SAFETY PRECAUTIONS 4 INTRODUCTION TECHNICAL DATA 5 PARTS IDENTIFICATION 6 7 CONTROL PANEL 8 INSTALLATION 9 11 OPERATION INSTRUCTIONS 12 13 REMOTE CONTROL 14 CARE AND MAINTENANCE 15 TROUBLES...

Page 3: ...product can be obtained from your local municipal au thority Thank you for choosing the Whynter 12 000 BTU Portable Air Conditioner Dual Hose with 3M and Silvershield filter Please follow the instruc...

Page 4: ...sh the exhaust hose while in use Always allow at least 20 of clearance around the unit for ventilation Do not use this unit inside closets cabi nets and or cramped spaces between furniture This unit i...

Page 5: ...ditioner can help cool a room faster and will help minimize a negative air pressure situation in the room If the outside temperature is much higher or more humid than the room the intake hose can be d...

Page 6: ...nt Air Vent Louvers Casters four Handle Upper Air Filter Power Cord Lower Air Filter Upper Air Intake Upper Drain Port Intake Hose Pre filter Air Exhaust Air Intake Lower Drain Port Power Plug Socket...

Page 7: ...t trip and the unit comes on please contact technical support 3 Press the RESET button to start the air conditioner 4 Do NOT use the TEST and RESET buttons to turn the air conditioner on and off ACCES...

Page 8: ...air flow direction Up and Down Buttons Adjusts set temperature 1 C 2 F increments or timer hours 0 24 hours This unit is capable of displaying the set temperature in Fahrenheit or in Celsius To conver...

Page 9: ...age Fig 1b Remove the upper drain plug from the back of the unit and install the drain hose Place the open end of the hose to a drain area This method is recommended if uninterrupted op eration is des...

Page 10: ...into the hole seats See Fig 2 4 Only extend the exhaust hose to the necessary length keeping it as short and straight as possible WINDOW KIT INSTALLATION The window kit has been designed to fit most s...

Page 11: ...seal adhesive type to the proper length and attach it to the bot tom of the door window Fig 6a 3 Adjust the length of the window bars to the same length and width of the opening of the window Cut the...

Page 12: ...cover and it will function like a single hose unit DRY DEHUMIDIFYING ONLY MODE In this mode the air conditioner only dehumidifies the room the compressor will activate intermittently depending on the...

Page 13: ...s To activate this function mode press the SLEEP button until the SLEEP indicator light comes on AUTO RESTART In the event of a power outage the air conditioner restarts at the previously set function...

Page 14: ...ays the current selected mode Auto Cool Dry or Fan 2 Transmission Indi cator Displays when remote sends signal to unit 3 ON OFF Display Displays when the unit is turned on and disappears when it is tu...

Page 15: ...mation WARNING Never operate the air conditioner without the filter in place CLEANING THE AIR CONDITIONER Always switch off the air conditioner and disconnect the plug from the power supply outlet bef...

Page 16: ...its time delay The set temperature is too high The internal water reservoir is full and P1 appears on display This unit is designed to work in ambi ent temperatures of 63 F to 90 F Press the MODE butt...

Page 17: ...it is very noisy The unit is not level The surface underneath the unit is uneven Low power voltage Make sure the unit is on hard level and stable surface Move the unit to a location with a level and h...

Page 18: ...in commercial or industrial applications Damage accidental or otherwise to the product while in the possession of a consumernot caused by a defect in material or workmanship Damage caused by consumer...

Reviews: