OPERATION INSTRUCTIONS

 

SWITCHING ON/OFF THE AIR CONDITIONER 

The appliance can be switched ON or OFF by pressing the POWER button on the control panel or the ON/OFF button on the remote 
control 

COOLING MODE

In this mode, the air conditioner cools and dehumidifies the room. To activate this function mode, press the MODE

 

button until the COOL indicator light comes on. When the cooling mode is set, the compressor will start in approximately 3 minutes. 
In cooling mode, hot air is exhausted from the outdoor exhaust port and the exhaust hose must be connected to exhaust out the 
hot air. The temperature setting range of this air conditioner is from 6

1

°F / 1

6

°C to 

89

°F / 3

2

°C. To set the temperature,

 

press the +

 

or 

-

 buttons. This air conditioner has a 5°F temperature cushion which if the set temperature is within 5°F of the ambient 

temperature, the unit runs on fan only mode. This saves energy and prolongs the life of the compressor of the air conditioner. To set 
the fan speed, press the FAN button. 

NOTE: In cooling mode, the difference in noise level between the fan speeds is not very noticeable when the compressor is on. Try 
setting the unit to Fan only mode, you should be able to hear the difference between high and low fan speed settings. 

DRY (DEHUMIDIFYING) ONLY MODE 

In this mode, the air conditioner only dehumidifies the room, the compressor will activate intermittently depending on the ambient 
temperature and the fan speed is set to LOW. To activate this function mode, press the MODE button until the DRY indicator light is 
displayed. Please note that when switching function mode, there will be an approximately 3 minute transition time. In dehumidi-
fying mode, the exhaust hose does not need to be vented. If the exhaust hose is vented, the room will be cooled as it dehumidifies. 
To prevent cooling, remove the exhaust hose from the window kit and allow the warm air from the rear to be recirculated into the 
room. If room temperature is higher than 77°F, the fan speed can be adjusted. If room temperature is lower than 77°F, the fan 
speed is set at Low.

 

NOTE: When using dehumidifying mode, venting the exhaust hose to the outside is not required. If vented, the warm air is exhaust-
ed to the outside and cooling within the room may occur. Additionally, if the exhaust hose is not vented, the unit may require more 
frequent draining. Also, the air conditioner does not have a humidistat in which a specific humidity level can be set.

FAN ONLY MODE 

In this mode, only the fan of the air conditioner runs and circulates the air in the room. To activate this function mode, press the 
MODE button until the FAN indicator light comes on. In this function mode, the temperature cannot be set. Subsequently, set the 
desired fan speed by pressing the FAN button. When using FAN only mode, venting the exhaust hose to the outside is optional.

 

TIMER (DELAYED SWITCH ON / OFF) FUNCTION 

This function mode enables a delayed switch ON or delayed switch OFF of the air conditioner. The time (hours) delay can be set, 
enabled and disabled. 

SETTING SWITCH OFF TIMER 

With the air conditioner operating in any function mode, press the TIMER button. The TIMER OFF light will come on. Then set 
the desired time delay OFF hours by pressing the UP and DOWN buttons. The time increments are at 0.5 hour to up to 10 hours, 
fol-lowed by 1 hour increment up to 24 hours. When the delay time set has elapsed, the air conditioner switches off. To cancel 
the delayed switch off function, turn off the air conditioner or adjust the time setting to 0.0. 

SETTING DELAYED SWITCH ON TIMER 

With the air conditioner is off, press the TIMER button. The TIMER ON light will come on. Then set the desired time delay ON 
hours by pressing the UP and DOW N buttons. The time increments are at 0.5 hour to up to 10 hours, followed by 1 hour 
increment up to 24 hours. When the delay time set has elapsed, the air conditioner switches on. To cancel the delayed switch on 
function, turn on the air conditioner or adjust the time setting to 0.0. 

10

Summary of Contents for ARC-115WG

Page 1: ...table Air Conditioner Model ARC 115WG Congratulations on your new Whynter product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in...

Page 2: ...THE RIGHT LOCATION AMBIENT TEMPERATURE RANGE FOR UNIT OPERATION TECHNICAL DATA ACCESSORIES WINDOW KIT INSTALLATION FILTER INSTALLATION AND DRAINAGE CONTROL PANEL OPERATION INSTRUCTIONS REMOTE CONTROL...

Page 3: ...tate moving Make sure not to use the wheels on thick carpet or to roll over objects as these could cause tipping Do not operate a unit that it has been dropped or damaged Do not place the portable air...

Page 4: ...Support for replacement parts compatible with your unit Turn off the product when not in use WARNING The appliance shall be stored in a room without continuously operating ignition sources for example...

Page 5: ...Your installation location should meet the following requirements Make sure that you install your unit on an even surface to minimize noise and vibration The unit must be installed near a grounded pl...

Page 6: ...icates the amount of heat it can remove from a room A higher Why is the cooling capacity lower on newer models than on older units number means more cooling power for a larger room Be sure you are com...

Page 7: ...it into the exhaust port of the rear panel and push the lock switch to lock the hose assembly firmly in place 2 Insert window panels B and C to each end of the main panel A with the exhaust port cut o...

Page 8: ...less than 70 Areas with more than 70 humidity the self evaporating function can still exhaust about 98 of the moisture and the remaining 2 of moisture will be collected in the water tank of the air c...

Page 9: ...SWING button to stop the louver at a desired angle LED Display Shows the set temperature in F or C and the Auto timer settings While on FAN modes it shows the room temperature Tank Full If the intern...

Page 10: ...be recirculated into the room If room temperature is higher than 77 F the fan speed can be adjusted If room temperature is lower than 77 F the fan speed is set at Low NOTE When using dehumidifying mo...

Page 11: ...F 95 F 16 C 35 C The compressor circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly This prevents over heating of the compressor and possible circuit breaker...

Page 12: ...oing so causes electrical danger DO NOT operate the portable air conditioner if the power supply was damaged during cleaning A damaged power cord must be replaced with a new cord Contact Whynter Custo...

Page 13: ...nal connection Please contact Whynter for service TIPS 1 Keep the exhaust hose as short and straight as possible The exhaust hose removes heat from the room It should remain as short and straight as p...

Page 14: ...ear the differ ence between high and low fan speed settings The air coming out of the unit is not very cold or the airflow volume is weak The filters are dirty or obstructed The air intake or exhaust...

Page 15: ...er surge low voltage defective household wiring or inadequate fuses Use in commercial or industrial applications Damage accidental or otherwise to the product while in the possession of a consumer not...

Reviews: